User's Manual

(4-6) Set Misc. Set RF Jamming Warning
Check ROM Version
Reset To Factory Default Enter to Reconfirm
Emergency Button Assignment
Set Inactivity Inactivity ON Inactivity Time
Set Password Inactivity OFF
Set Modem Ring Count= 1~30
Set SW #16 Arm/Disarm =ON
RF Jamming Warning: (default, OFF) Enable or disable the RF jamming warning.
Reset To Factory Default:
All the settings in the Base Unit will be returned to factory default except recorded voice and
telephone numbers.
Emergency Button Assignment: Panic /Medical (default, Panic)
Select the function of the Emergency Button as a Panic Button or a Medical Button (The zone
number of this button is 00-05.).
Set Inactivity: ON /OFF (default, OFF)
Inactivity On with time (0-72 hours):
1, Treats the Inactivity signal from the Wireless Medical Button as a Medical Alarm.
(The Medical Button will send Inactivity signal if no activity has been detected in 12 hours.)
2, If no activity has been detected during this time from any Inactivity Sensor (Refer to (4-4-1)
Change Device Setting-Burglar Sensor-Enable State-Inactivity) the system will issue the
Inactivity Medical Alarm (with zone number of 00-06).
Inactivity Off: Ignore the Inactivity signal from the Wireless Medical Button and don’t check
the Inactivity Timer.
Set Password: (default, “1234”) Edit the Installer Password.
Set Modem–Ring Count (1-30): (default, Ring Count=3)
This setting is only valid for the system equipped with an optional Data Communication Module.
After this ring count number the Module will connect (off hook) to the telephone line automatically.
Note: After this ring count has been set, user should connect the Module to the system then enter
Master Mode and press Hotkey “C” (clear status) to pass this parameter to the Module.
Set SW #16: (default, ARM ON): Set the #16 switch as an Arm/Disarm status indicator.
Arm On: The #16 switch will be turned on in Away and Home Mode.
Disarm On: The #16 switch will be turned on in Disarm and Monitor Mode.
32