User's Manual
(4-4-1) Change Device Setting Controller Change
Burglar Sensor Change Enter Zone Number
Fire Sensor Change Enable State
Medical Button Change Zone Number
Special Sensor Change Switch Control
Enable state of devices:
Device On Duty/Bypass (default, On Duty): (For all devices)
Device On Duty: This sensor is working in the system currently.
Device Bypass: Bypass this sensor; the system will ignore the alarm signal received from this sensor.
Delay ON/OFF (default, Delay=OFF): (For Controller & Burglar sensor)
Delay ON: (Refer to (4-1) Set Timer - Exit Delay/Entry Delay.)
For the Remote Controller, the Exit Delay time will be imposed on the Away command from
this controller.
For the Burglar sensor, the Entry Delay time will be imposed on the Burglar alarm signal from
this sensor.
Delay OFF: The trigger signal or command from this sensor or controller will be processed
immediately, regardless of the Exit/Entry Delay setting in (4-1).
24-Hour Zone YES/NO (default, 24-Hour Zone= NO): (For Burglar sensor)
24-Hour Zone/YES: This Burglar sensor’s trigger signal will be processed all the time regardless of
the system’s operation mode, either in Arm or Disarm.
24-Hour Zone/NO: This sensor’s trigger signal will only be processed in Arm Mode.
Home Mode Active/Inactive (PIR default= Inactive, Magnet default= Active): (For Burglar sensor)
Home Mode Active: This Burglar sensor will trigger an alarm in Home Mode operation.
Home Mode Inactive: This Burglar sensor will not trigger an alarm in Home Mode operation, it
will only trigger an alarm in Away Mode operation.
Pre-warning ON/OFF (default, Pre-warning OFF): (For Burglar Sensor)
Pre-warning ON: When this device is triggered in Arm condition, it only turns on the corresponding
switches those set by this device for 30 seconds to warn the person who approaching the
protected area. (If 24-Hour Zone set, the switches will turn on anytime when this device is
triggered.). It won’t trigger burglar alarm.
Voice Warn ON/OFF (default, Voice Warn ON): (For Fire, Medical and Special alarm sensors)
Voice Warn ON: If this sensor triggers an alarm, there will be a 30-second voice warning from the
Base Unit before the alarm reaction procedure starts.
Voice Warn OFF: There is no voice warning. The Base Unit responds immediately when there is an
alarm triggered by this device.
Siren/Relay ON/OFF (default, Siren/Relay ON, only OFF for Controller): (For all devices)
Siren/Relay ON: The Relay will act and sirens (both Inner Siren and Remote Siren) will go off
when there is an alarm triggered by this sensor after the Delay time or Voice Warning passes.
Siren/Relay OFF: The Relay will not act and sirens will keep silent when there is an alarm triggered
29