User's Manual
2). When the Base Unit detects AC power break or restore, this number will be dialed after a random
delay of 60-120 seconds, The pre-recorded messages (power loss/power restore) will be played when the
call is successfully connected.
Pause Insertion
Note: Use the Pause key to insert pauses between telephone number digits for dialing
to/from a PABX extension number. Each pause is equivalent to a 3-second break.
Answering status: Voice /Tone (default, Voice).
After dialing, the LS-30 needs an acknowledgement from the called party, either by voice
like “Hello” or by a DTMF key tone to ensure the call is connected successfully. With no
acknowledgement, the call will be deemed to be failed and will be redialed in the next loop.
Dialing Sequence for Alarm Report
CMS1 Number →
→→
→ CMS2 Number →
→→
→ Pager →
→→
→ Specific alarm number →
→→
→ 1st to 4th
Common numbers
If there is any number that cannot be connected successfully, the auto-dialer will skip to the
next one and try again in the next loop until all the numbers have been tried 5 times or the
cease dialing condition has been reached. (refer to (4-2) Set Telephone - Set Cease Dialing
Mode.)
Note: 1, CMS1 and CMS2 are Central Monitoring Station numbers (refer to the (5) CMS Mode).
2, If Ethernet Report has been set (refer to (5) CMS Mode-Set CMS1-Ethernet
Report) the alarm report will be sent to Internet CMS Server first before any alarm
report through PSTN.
25