User's Manual

Entry Delay for Burglar Sensors: (0-255 seconds, default=0 sec.)
This setting is the time between any burglar sensor triggers and the alarm reaction procedure starts.
When you return home and open the door, the Base Unit will issue warning beeps (if the Entry
Delay Beep = On) to remind you that the system is still in the Arm state and you should disarm the
system within this time. (Refer to the (4-3) Set Sound - Entry Delay Beep.)
AWAY Mode Entry Delay Burglar Alarm
System status:
(0-255 seconds)
Burglar sensor triggered Siren goes off, dialing---
This Delay only works on the Burglar Sensor with its Delay ON/OFF setting in ON state.
(Refer to (4-4-1) Change Device Setting - Burglar Sensor - Enable State - Delay ON/OFF.)
For the system controlled by Wireless Keypad, this timer should be set more than 20 seconds.
Exit Delay for Controllers: (0-255 seconds, default=0 sec.)
This setting is the time between selecting the AWAY mode and when the AWAY arm
becomes effective. During this time, the Base Unit will issue warning beeps to remind the
people still in the house to leave as soon as possible.
Since the Door Open signal may last for 10 seconds, so add 10 seconds to the time you need to
leave the house as the Exit Delay. (Ex. you need 20 seconds to leave the house, set Exit Delay=30s)
Disarm Exit Delay AWAY ARM effective
System status:
(0-255 seconds)
Set AWAY mode
This Delay only works on the Controller with its Delay ON/OFF setting in ON state.
(Refer to (4-4-1) Change Device Setting-Controller-Enable State-Delay ON/OFF)
For the system controlled by Wireless Keypad, this timer should be set more than 20 seconds.
Inner Siren Time: 0-255 seconds (default, 60 sec.)
The time of the Inner Siren sounds when an alarm trips and Inner Siren is enabled.
(Refer to (4-5) Set Siren-Set Inner Siren.)
Relay Action Time: 0 second to 120 minutes (default, 60 sec.)
The activation time of the Alarm Relay output (on the rear panel) when the alarm trips.
Sensor Supervise Time: 0-24 Hours (default, 12 Hours)
The LS-30 is a supervised RF wireless system, meaning supervised sensors send “heartbeat” RF
signals to the Base Unit at a certain time interval. If the Base Unit does not receive the RF check
signal from a supervised sensor within the Sensor Supervise Time, the LS-30 considers this
sensor to be missing and issues a warning message.
This time can be set from 0 to 24 hours (0 hour means that the system will not check the “heartbeat”
signal.
Please note, the time shorter than 4 hours would increase sensor “RF Loss” possibility.
Remote Siren Time: 0 seconds to 30 minutes (default, 60 sec.)
The time of the wireless Remote Siren sounds when the alarm trips. (The Remote Siren is an
Option.)
21