REACTION OF LS-30 TO DIFFERENT ALARMS
The response of the LS-30 to various alarms and abnormalities is shown below. Burglar alarms can only be
issued when the system is in AWAY or HOME mode, while Fire, Panic, Medical and Special alarms can be
triggered anytime, regardless of the system operation mode. When any of these alarms occur, the LS-30 will
dial the correct phone numbers to call for help.
Burglar Alarm Response
AWAY Mode Entry Delay Burglar Alarm →
System status:
↑ (0-255 seconds) ↑
Burglar sensor triggered Siren goes off, dialing---
If necessary, you can interrupt dialing and stop the siren by disarming the system, and clear the alarm
LED/LCD by pressing (Hot Key)
Press (Hot Key) : stop siren, stop dialing, clear LED/LCD status.
Sources &
Responses
Alarm
Trigger Sources Dialing Tel. Numbers
Besides CMS
Voice message
on telephone
Voice on
Base Unit
Siren Status
Burglar
PIR
Door Magnet
Glass Break Detector
Vibration Sensor
Pager+ Burglar+ Common
1-4+
Burglar+ Common
Silent
Programmable,
Fire Smoke Detector
Gas Detector
CO Detector
Pager+ Fire+ Common
1-4+
Fire+ Common
Fire Message
Programmable
Programmable,
Panic Panic button of
Remote Controller
Wireless Keypad
Emergency buttons on
Base Unit
Pager+ Panic+ Common
1-4+
Panic+ Common
Silent
Programmable,
* Siren off
Medical Wireless Medical Button
Inactivity
Pager+ Medical+Common
1-4+
Medical+ Common
Medical
Message
Programmable
Programmable,
Special Temperature Sensor
Humidity Sensor
Flood Detector
Light Detector
Analog Sensor
Power Meter
Pager+ Special+ Common
1-4+
Special+ Common
Special
Message
Programmable
Programmable
(Disarm State)
None
None
Silent Programmable
Sensor Tampered
All sensors
(Arm State)
Same As Burglar Alarm
Sensor Trouble or Low
Battery
All sensors None None Silent OFF