User's Manual

(3) Master Mode Set Bell Door Bell On
Device Test Door Bell Off
Set Monitor Mode Monitor Mode (Only can be entered in Disarm Mode)
Set Partial ARM Disarm Mode
COM1 Control COM1 On/Off Need Password?
Set Entry Delay (Refer to (4-1) Set Timer- Set Entry Delay.)
Set Exit Delay (Refer to (4-1) Set Timer- Set Exit Delay.)
Set Clock Time Date Day
Set Switch X-10 Set House Code
Type2-Type5 Set Switch Auto Control
(Reserved)
*Deny Arm if not Ready
Set Password Master
User 2 ~ User 8
User 9, 10 (Latchkey User)
User 11(Duress Code)
Bell ON/OFF (default= ON): Enable/Disable the doorbell chime.
Bell ON: In Disarm Mode, the Base Unit will issue a doorbell sound (Ding! Dong!) when receiving a
triggering signal from a Burglar sensor with its Bell ON/OFF status set in the ON state.
Bell OFF: No doorbell chime will sound.
Note: The Bell function only works for the Burglar Sensor if its Bell ON/OFF status is set in the ON
state. (refer to (4-4-1) Change Device Setting-Burglar Sensor-Enable State-Bell ON/OFF.)
Device Test: The system opens a 5-minute test window for the user to test the operation of all the sensors
(not including the Remote Controller and Keypad). In this period, when the Base Unit receives any
signal from the sensors, it will only sound beeps and not trigger any alarm. When the 5 minutes are
over, the system returns to its original operation mode automatically. The system will escape from the
test mode immediately when it receives an Arm/Disarm signal.
13