User's Manual
A-7. Using the same telephone line to connect the LS-30, a Fax machine and a Telephone
Answering
Machine (TAM)
(Only available for the PCB version after LS30-02A)
Telephone Line
To Phone
Fax TAM Phone set
The LS-30 Base Unit, a Fax Machine and a TAM can be connected to the same telephone line
and all these devices will still be able to accept their own dial-in control signal.
1. The auto answering ring counts (Refer to (4-2) Set Telephone-Set Auto Answer for LS-30)
should be set as:
LS-30 ring count> Fax ring count >TAM ring count.
Ex. If the ring count of the LS-30 is 8, the ring count of the Fax should be 6 and ring count of
TAM should be 4.
2. Set the operation mode of the Fax machine in TAM mode. (Please refer to the manual of the Fax
machine.)
3. When you dial in, the TAM will connect first.
If you want to record a message on the TAM, just do it.
If you want to send a Fax, just press the send button on the Fax machine.
If you want to control the LS-30 system, after the announcement from the TAM is over (or
the Fax tone from the Fax machine is over) then key in the password, and the LS-30 will take
control of the telephone line.
Note: The Line Cut Detection function should be disabled (Refer to (4-2) Set Telephone-Set
Telephone Line Cut Detection-Permanent Off), otherwise the LS-30 will trigger the
line cut detection alarm when the TAM or Fax has taken control of the telephone line.
A-8. Partial Arm for Group Numbers “91” to “99”
The Group Numbers from “91” to “99” can be set as partial arming zones by a Remote Controller, the
Panel keyboard or through the HyperSecureLink software individually. They are independent of the
main groups (Group Number “01”~”89”).
The Remote Controller with Group Number ”9x” only controls the corresponding burglar sensors with
the same Group Number ” 9x”. For example, Remote Controller with Group Number “ 91” only controls
(Away, Home, Disarm) the burglar sensors with the Group Number “91”.
When the LS-30 receives an AWAY/HOME/DISARM signal from the Remote Controller of Group
Number “9x”, the Base Unit will announce the Away/Home/Disarm operation, but the LCD and LEDs
(Green, Red and Yellow) will only follow the status of the main groups (Group number ” 01”~”89”),
unaffected by the status of Group Number “91”~”99”.
38