User's Manual
Appendix E: Load Factory Default of Internet Adaptor
If user forgot the Device ID/ Password, the LS-10 works abnormally or couldn’t be found by VCOM
software then user can load the Factory Default to re-initialize the device.
D.1, Disconnect the power/data cable from the LS-10
D.2, Open the cover of the LS-10.
D.3, Take out the Jumper from JP3 (Remember the position of the Jumper on JP3) and put the Jumper on
JP1
D.4, Apply the power to LS-10 for 3 seconds.
D.5, Disconnect the power/data cable.
D.6, Put the Jumper back to the original position on the JP3.
D.7, Using Ethernet cable to Connect the LS-10 and PC directly as below.
D.8, Run the VCOM and you will see the device on the list.
Note: If the PC and the LS-10 are not in the same IP segment then “Search IP Address” will be blank
and the little “Searching” screen will not show.
Ex: If the IP address of PC is 192.168.0.x and the default address of LS-10 is 192.168.2.xx then
“Search IP Address” will be blank as below.