User's Manual

Appendix B: Partial Zone Control
B.1 Set Partial Zone Operation Mode:
Groups 91 to 99 are nine independent protected zones and these zones can be Armed /Disarmed
individually.
Setting of Partial Zone Operation Mode from HyperSecureLink software
The Group Numbers from “91” to “99” are partial arming zones. They can be controlled by a Remote
Controller, Wireless Keypad, or through the HyperSecureLink software individually but independent of
the main groups (Group Number “01”~”89”).
The Remote Controller or Wireless Keypad with Group Number ”9x” only controls the corresponding
burglar sensors with the same Group Number ” 9x”. For example, Remote Controller with Group
Number “ 91” only controls (Away, Home, Disarm) the burglar sensors with the Group Number “91”.
When the LS-10 receives an AWAY/HOME/DISARM signal from the Remote Controller of Group
Number “9x”, the Base Unit’s LEDs (Green, Red and Yellow) will only follow the status of the main
groups (Group number ” 01”~”89”), unaffected by the status of Group Number “91”~”99”.
B.2 Partial Zone control by KP-3S Operation Scene Control function
Setting Operation Scene from HyperSecureLink software
1, Set Operation Scene from HyperSecureLink software.
Ex. Scene 1: Main Zone and partial zone 91,92,93 are in Away Mode, other partial zones are
in DisarmMode.
Scene 2: Main Zone in Disarm Mode and partial zone 91, 92 and 93 in Away mode,
other partial zones are in Disarm mode
2, Select Scene from the KP-3S (Please refer to the KP-3S user Guide.)
Note: Before using the Scene Control on the KP-3S, you have to press the A and B keys
simultaneously for 3 seconds then press 1 on the KP-3S to enable this function first.
Operation Scene Control:
Key entry Enter PSW Press Press scene number (1to8)
Indication/sound Green LED on Yellow LED on Green LED flashes 1.5s/ 2 beeps
Base Unit action Main and 91-99 zones enter preset state.