User's Manual

8.8 Switch Settings
*Switch Type (Default X-10 type):
House Code <A-P>: (X-10 Type switch only, default <A>)
This code should be the same as the House Code set on the X-10 switches, user can select from A to P.
8.9 MISC. Settings
* Deny Arm If Not Ready: (default, No)
If set yes then system will not enter into Away or Home Mode if not all the
Door/window Magnet s are closed.
Note: If Away or Home control is remotely issued by command from HyperSecureLink,
App. , or Cloud then system will not care about this setting and enter the Arm Mode
immediately.
*RF Jamming Warning: (default, Disable) Enable or disable the RF jamming warning.
*Reset To Factory Default:
All the settings in the Base Unit will be returned to factory default.
*Inactivity Function: (default, Disable)
Inactivity Enable with time (0-72 hours):
1, Treats the Inactivity signal from the Wireless Medical Button as a Medical Alarm.
(The Medical Button will send Inactivity signal if no activity has been detected in 12 hours.)
2, If no activity has been detected during this time from any Inactivity Sensor (please refer to
8.4 Device Status Setting-Inactivity) the system will issue the Inactivity Medical Alarm
(with zone number as 00-06).
Inactivity Disable: Ignore the Inactivity signal from the Wireless Medical Button and dont
check the Inactivity Timer.
*#16 SW Assignment: (default, ARM=ON): Set the #16 switch as an Arm/Disarm status indicator.
Arm= On: The #16 switch will be turned on in Away and Home Mode.
Disarm= On: The #16 switch will be turned on in Disarm and Monitor Mode.