User's Manual
8.4 Device Status Settings:
*Device Bypass (default= No): (For all devices)
Bypass = Yes: The system will ignore the trigger signal from this sensor.
*Delay Activation(default= Yes): (For Controller & Burglar sensor)
Delay Activation =Yes: (Refer to Exit Delay/Entry Delay.)
For the Remote Controller, the Exit Delay time will be imposed on the Away command from
this controller.
For the Burglar sensor, the Entry Delay time will be imposed on the Burglar alarm signal
from this sensor.
Delay Activation=No: The trigger signal or command from this device will be processed
immediately, regardless of the Exit/Entry Delay Time.