Certificate

Note 17C - The Printed Wiring Board assembly has not been evaluated, the acceptabili
ty for use with end-product and spacings shall be determined
in the end-product application.
Note 17D - IP 52 testing was completed on the exposed switch parts and gasket to the end product enclosure. The mounting method was a
rectangular opening 36.2 by 21.0 mm with material 3.1 mm thick. Internal parts were not evaluated for IP ratings and shall be considered in the end
product.
Note 2 - The suitability of the actuator button material as an enclosure has not been investigated.
Note 2A - UL61058-1 - These switches employ Quick Connected or Soldered terminals, the terminals have been investigated for use with stranded
conductors of specified sizes 2.5 mm2 only for all cat. nos.
Note 2B - UL61058-1 - These switches employ Quick Connected or Soldered terminals, the terminals have been investigated for use with Rigid
conductors of specified sizes 4.0 mm2 only for all cat. nos.
Note 2C - UL61058-1 - These are lighted switches employing a lamp. The usable lamp life has not been evaluated.
Note 2D - UL61058-1 - Heating test was conducted at ambient temperature of 85 deg C, the suitability of wire conductors using on the switches
terminals shall be determined in end-product applications.
Note 3 - Terminations other than solder connections should be evaluated for compliance with the end-use product standard.
Note 4 - The load is to be connected across the switch terminals in such a manner that each of the poles will break the same circuit, see Appendix
FS, circuit B.
Note 4A - UL61058-1 - When mounted in accordance with the manufactures instruction, this switch gets a protection degree of IP40, also if Dust
cover removed, IP40 still available.
Note 4B - UL61058-1 - The switch is to be employed in an end use product providing an enclosure or insulating barrier that provides Reinforced or
Double Insulation over the front and rear switch enclosure Surfaces.
Note 4C - UL61058-1 - These are lighted switches employing a lamp across disconnection terminal "b".
Note 4D - UL61058-1 - Heating test was conducted at ambient temperature of 85 degC with measured maximum temperature of 92.6 degC on
terminals, the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Note 5 - These switches have a contact gap exceeding 3mm.
Note 5A - UL61058-1 - The Switch body is installed inside of end product; only consider the Rocker as accessible parts.
Note 6 - These switches may be provided with a light. Lamp life has not been evaluated.
Note 6A - UL61058-1 - The terminals have been evaluated for use with 2.5 mm2 flexible stranded and 4.0 mm2 rigid conductors.
Note 6B - UL61058-1 - The Switch body is installed inside of end product; only consider the Rocker as accessible parts.
Note 6C - UL61058-1 - Heating test was conducted at ambient temperature of 85 degC with measured maximum temperature of 104.6 degC on
terminals, the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Note 7A - UL61058-1 - The terminals have been evaluated for use with 1.5 mm2 flexible stranded and 2.5 mm2 rigid conductors.
Note 7B - UL61058-1 - The Switch body is installed inside of end product; only consider the Toggle as accessible parts.
Note 7C - UL61058-1 - Heating test was conducted at ambient temperature of 85 deg C with measured maximum temperature of 100.4 deg C on
terminals, the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Note 8 - These switches shall be mounted on or supported by a plastic material enclosure suitable for direct support of live parts.
Note 8A - UL61058-1 - The Switch body is installed inside of end product; only consider the Rocker as accessible parts.
Note 8B - UL61058-1 - Heating test was conducted at ambient temperature of 85 degC with measured maximum temperature of 125.4 degC on
terminals, the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Note 8C - UL61058-1 - IP 40 for accessible parts and enclosure of the end product enclosure when mounted or installed according to the
manufacturers directions. Internal parts were not evaluated for IP ratings and must be considered in the end product.
Note 9 - These switches employ a lamp that is powered by a separate DC source. Lamp DC source should be evaluated for compliance with the
end-use standard.
Note A1 - The switch having three poles connected Test Circuit B and Test Circuit A was subjected to the subject evaluation.
Note A4 - The Printed Wiring Board assembly has not been evaluated, the acceptability for use with end-product and spacings shall be determined in
the end-product application.
Note A5 - The Linking Sheet has not been evaluated, the acceptability for use with end-product and spacings shall be determined in the end-product
application.
Notes 12A - When mounted in accordance with the manufactures instruction, this switch gets a protection degree of IP 40.
Notes 12B - The Switch body is installed inside of end product; only consider the Actuator as accessible parts.
Notes 12C - Heating test was conducted at ambient temperature of 85 deg C with measured maximum temperature of 87.8 deg C on terminals,
the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Notes 13A - When mounted in accordance with the manufactures instruction, this switch gets a protection degree of IP 40.
Notes 13B - The Switch body is installed inside of end product; only consider the Actuator as accessible parts.
Notes 13C - Heating test was conducted at ambient temperature of 85 deg C with measured maximum temperature of 100.8 deg C on terminals,
the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
^Note 1 - UL61058-1 - These are lighted switches employing a lamp. The usable lamp life has not been evaluated.
^Note 2 - UL61058-1 - The device is factory wiring with terminals that do not allow the wire to be removed once inserted.
^Note 3 - UL61058-1 - Only the Button is considered as accessible parts to users. For rest parts of the switches that shall be enclosed with a
suitable enclosure, and the acceptability shall be determined in end-product applications.
WOYR2.E67774 - Switches, Appliance and Special Use - Component
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/show...