10 250 60 1/2hp 6K
R13-901 6 125 60 GP 6K 55 1/1 -/- -
3 250 60 GP 6K
R13-915 5 125 60 GP 6K 65 1/1 -/- -
- 250 60 1/4hp 6K
R13-918B-02 16 125 60 GP 6K 105 1/1 -/A -
10 250 60 GP 6K
- 125 60 1/3hp 6K
- 250 60 1/2hp 6K
R14-6S, R14-6Q w/ wo 1 or 2
5 125 60 GP 6K 65 1/1 -/- Note 1, 2, 3
3 250 60 GP 6K
16A - IP65 and IP40 - for accessible parts and enclosure of the end product enclosure when mounted or installed according to the manufacturers
directions. Internal parts were not evaluated for IP ratings and must be considered in the end product.
16B - The Switch body is installed inside of end product; only consider the Actuator as accessible parts.
16C - Heating test was conducted at ambient temperature of 85 deg C with measured maximum temperature of 119.7 deg C on terminals, the
suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
20A - IP 4X testing was completed on the complete switch without an end product enclosure. The switch gasket (seal) to the end product
enclosure is evaluated in the end product testing.
22A - IP 40 testing was completed on the complete switch without an end product enclosure. The Inner Boot must be provided to maintain the
IP40 function. The switch gasket (seal) to the end product enclosure is evaluated in the end product testing.
22B - During the wiring installation for M4 Screw, the switch terminals need to fix by jig or tool before screw tightly.
9A - The lighted switches rated DC rating only employing DC lamps; the lighted switches rated AC rating only employing AC lamps.
9B - The Switch body is installed inside of end product; only consider the Actuator as accessible parts.
9C - Heating test was conducted at ambient temperature of 85 deg C with measured maximum temperature of 108.8 deg C on terminals, the
suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
9D - After 6K Endurance cycles, the switches rated 20RA, 125 V ac were evaluated for temperature test at 18 A only.
9E - The switches get a protection degree of IP 66 in accordance with the manufacturer's mounting means only. For IP 6X dust test, talcum
powder did enter the mounting enclosure and deposited on terminals of the switch but the talcum powder did not enter the switch housing. The
suitability of mounting means for the switches shall be determined in end-product applications.
A2 - The construction applied for the rating 16 A and 14 A is different. The spring with 12.5 mm long is used for 14/10 A, 125/250 V ac; 1/3 hp,
125 V ac; 1/2 hp, 250 V ac. The spring with 13.3 mm long is used for 16/10 A, 125/250 V ac; 1/3 hp, 125 V ac; 1/2 hp, 250 V ac.
A3 - Waterproof should be evaluated for compliance with the end-use product Standard.
Note 1 - The switch terminals have not been investigated for printed circuit board connections. The suitability of these terminals should be
evaluated for compliance with end-use product standard.
Note 10 - The Models R13-112B8W, R13-112C8 and R13-112A8 had a water proof cover part, but were not tested as part of this investigation.
The suitability of the water proof cover must be determined in accordance with the end product Standard.
Note 10A - When mounted in accordance with the manufactures instruction, this switch gets a protection degree of IP 40.
Note 10B - The Switch body is installed inside of end product; only consider the Actuator as accessible parts.
Note 10C - Heating test was conducted at ambient temperature of 85 deg C with measured maximum temperature of 101.8 deg C on terminals,
the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Note 11 - The screw terminals are not intended to be used for wire binding. They are intended to be used with crimp-on type connectors only.
Note 11A - When mounted in accordance with the manufactures instruction, this switch gets a protection degree of IP 65 for Proof Bushing
Construction with mounting enclosure opening 19.2 mm by 13 mm as mounting means, others gets IP40.
Note 11B - The Switch body is installed inside of end product; only consider the Actuator as accessible parts.
Note 11C - Heating test was conducted at ambient temperature of 85 deg C with measured maximum temperature of 111.1 deg C on terminals,
the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Note 12 - These are lighted switches employing a lamp. The usable lamp life has not been evaluated.
Note 14B - Heating test was conducted at ambient temperature of 85 degC with measured maximum temperature of 127.4 degC on terminals,
the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Note 16A - IP65 and IP40 - for accessible parts and enclosure of the end product enclosure when mounted or installed according to the
manufacturer's directions. Internal parts were not evaluated for IP ratings and must be considered in the end product.
Note 16B - The Switch body is installed inside of end product; only consider the Actuator as accessible parts.
Note 16D - Heating test was conducted at ambient temperature of 85 deg C with measured maximum temperature of 100.5 deg C on terminals,
the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Note 17A - The Switch body is installed inside of end product; only consider the Rocker as accessible parts.
Note 17B - Heating test was conducted at ambient temperature of 85 degC with measured maximum temperature of 121.2 degC on terminals,
the suitability of wire conductors using on the switches terminals shall be determined in end-product applications.
Page 2
3
of 2
5
WOYR2.E67774 - Switches, Appliance and Special Use - Component