Certificate
R 10 125,250 50-
60
T85/55 1/1,1/2-1.2 6K 10K --
R 10 125,250 50-
60
T85/55 2/1,2/2-1.3 6K 10K --
R13-427 f/b [M1] [M1]=[C, I, D, H or G; f/b 1, 2, 3, 4, 5, 6 or 7; f/b -01, -05, -08 or -12]
RM 12(4) 250 50-
60
T85/55 1/1-2.2 or 3.2 6K 10K 40 full
3.81
7A, 7B, 7C 2009-08-
10
R13-427 f/b [M2] [M2]=[A, N or R; f/b 1, 2, 3, 4, 5, 6 or 7; f/b -01, -05, -08 or -12]
RM 16(4) 250 50-
60
T85/55 1/1-1.2 6K 10K 40 full
3.81
7A, 7B, 7C 2009-08-
10
R13-428 f/b [M1] [M1]=[F, S or Q; f/b 1, 2, 3, 4, 5, 6 or 7; f/b -01, -05, -08 or -12]
RM 16(4) 250 50-
60
T85/55 2/1-1.3 6K 10K 40 full
3.81
7A, 7B, 7C 2009-08-
10
R13-428 f/b [M2] [M2]=[B, P, E, M or K; f/b 1, 2, 3, 4, 5, 6 or 7; f/b -01, -05, -08 or -12]
RM 12(4) 250 50-
60
T85/55 2/1-2.4 or 3.4 6K 10K 40 full
3.81
7A, 7B, 7C 2009-08-
10
R13-437 f/b A, C, D, G, H, I, N and R; f/b 1, 2, 3, 4, 8 or 9; f/b -01, -04, -05, -06, -07, -08 or -11
RM 16(4) 125-
250
50-
60
T85 1/1,1/2-1.2,3.2 6K 10K 40 full
1.5
9A,9B,9C,9D 2009-08-
10
RM 16(4) 125-
250
50-
60
T85/55 1/1,1/2-1.2,3.2 6K 10K 40
R13-438 f/b A, B, C, D, E, F, G, H, I, K, M, N, P, Q, R and S;f/b letter, number or blank,f/b 1, 2, 3, 4, 5, 6, 7 or 8;f/b
-01, -05, -06,-07, -08;f/b B .
RM 10(4) 125,250 50-
60
T85 1/1,1/2-1.2 6K 10K -- full
1.5
22A, 22B -
RM 10(4) 125,250 50-
60
T85 2/1,2/2-1.3 6K 10K --
RM 10(4) 125,250 50-
60
T85/55 1/1,1/2-1.2 6K 10K --
RM 10(4) 125,250 50-
60
T85/55 2/1,2/2-1.3 6K 10K --
R 10 125,250 50-
60
T85 1/1,1/2-1.2 6K 10K --
R 10 125,250 50-
60
T85 2/1,2/2-1.3 6K 10K --
R 10 125,250 50-
60
T85/55 1/1,1/2-1.2 6K 10K --
R 10 125,250 50-
60
T85/55 2/1,2/2-1.3 6K 10K --
R13-447 f/b [M1] [M1]=[C, I, D, H or G; f/b 1, 2, 3, 4, 5, 6 or 7; f/b -01, -05, -08 or -12]
RM 12(4) 250 50-
60
T85/55 1/1-2.2or3.2 6K 10K 56 full
3.81
7A, 7B, 7C,
8
2009-08-
10
R13-447 f/b [M2] [M2]=[A, N or R; f/b 1, 2, 3, 4, 5, 6 or 7; f/b -01, -05, -08 or -12]
RM 16(4) 250 50-
60
T85/55 1/1-1.2 6K 10K 56 full
3.81
7A, 7B, 7C,
7D
2009-08-
10
R13-448 f/b [M1] [M1]=[B, P, E, M or K; f/b 1, 2, 3, 4, 5, 6 or 7; f/b -01, -05, -08 or -12]
RM 12(4) 250 50-
60
T85/55 2/1-2.4or3.4 6K 10K -- full
3.81
7A, 7B, 7C,
8
-
R13-448 f/b [M2] [M2]=[F, S or Q; f/b 1, 2, 3, 4, 5, 6 or 7; f/b -01, -05, -08 or -12]
RM 16(4) 250 50-
60
T85/55 2/1-1.3 6K 10K -- full
3.81
7A, 7B, 7C,
7D
-
R13-452K-02 RM 7(7) 125 50-
60
55 2/1-1.3 6K 50K 40 full
1.5
Note 4 2005-09-
30
RM 3.5
(3.5)
250 50-
60
55 2/1-1.3 6K 50K 40
Marking: Company name or tradename "SCI" or trademark
, , , catalog, model or part number, electrical
ratings and the Recognized Component Mark, on the product or on the smallest unit container in which the product is packaged.
Investigated to ANSI/UL 1054
Page 1
2
of 2
5
WOYR2.E67774 - Switches, Appliance and Special Use - Component
28.07.201
7
htt
p
://database.ul.com/c
gi
-
b
in/XYV/tem
p
late/LISEXT/1FRAME/show
p
a
g
e.html?na
m
...










