User's Manual
Table Of Contents
- Table of Contents
- List of Tables
- List of Figures
- Figure1.1 Typical SEL3022 and SEL5810 Virtual Serial Software Application 1.2
- Figure1.2 Encrypted Packet Stream 1.4
- Figure1.3 Typical Connections for the SEL3022 1.6
- Figure1.4 Typical Alarm Output Installation 1.8
- Figure2.1 SEL3022 Dimension Drawing 2.2
- Figure2.2 Windows Run Command 2.3
- Figure2.3 Product Unregistered Prompt 2.4
- Figure2.4 Select a Device Type to Create 2.7
- Figure2.5 Specify New Device Location 2.8
- Figure2.6 Opening Device 2.8
- Figure2.7 Identification Screen 2.9
- Figure2.8 Status: Device 2.10
- Figure2.9 Settings: Wireless 2.10
- Figure2.10 Settings: WEP Keys 2.11
- Figure2.11 Settings: User 2.11
- Figure2.12 Settings: Operator 2.12
- Figure2.13 Settings: Security Officer 2.12
- Figure2.14 Confirm Send Prompt 2.13
- Figure2.15 Send Operation Message 2.13
- Figure2.16 Select Items to Print 2.14
- Figure2.17 Print Window 2.14
- Figure3.1 Remotely Located Recloser Control 3.2
- Figure3.2 Job Done Example SEL-5809 Top Level View 3.3
- Figure3.3 Select a Wireless Session for DNP3 Job Done Example 3.4
- Figure3.4 Settings: DCE Port 3.4
- Figure3.5 Status: Virtual Serial Port With Connection Status Red 3.5
- Figure3.6 Communication Parameters Window in acSELerator 3.6
- Figure3.7 Status: Virtual Serial Port With Connection Status Green 3.6
- Figure3.8 Reading Settings Via the SEL3022 3.7
- Figure3.9 Monitoring SEL651R Meter Data Via the SEL3022 3.8
- Figure3.10 Status: Virtual Serial Port Connection Status Red 3.9
- Figure3.11 Specify Device to Export to SEL5810 Virtual Serial Software 3.10
- Figure3.12 Export Encrypted User Configuration File 3.10
- Figure3.13 Store Encrypted File 3.11
- Figure3.14 Password Prompt in SEL5810 Virtual Serial Software 3.12
- Figure3.15 Communication Parameters Window in acSELerator 3.13
- Figure3.16 Reading SER Report Via acSELerator 3.14
- FigureB.1 PC to SEL3022 Connection B.2
- FigureB.2 SEL3022 and SEL-5809 Connection Parameters B.2
- FigureB.3 SEL5809 Settings Software Connection Method B.3
- FigureB.4 SEL-5809 Opening Connection B.3
- FigureB.5 Status: Device Window B.4
- FigureB.6 Confirmation Prompt B.4
- FigureB.7 Send Operation Prompt B.4
- FigureB.8 Configuring Serial Port Settings in the Terminal Software B.5
- FigureB.9 Send File Prompt B.6
- FigureB.10 Sending Confirmation Window B.6
- FigureB.11 Terminal Invalid Firmware Error Message B.7
- FigureB.12 Terminal Valid Firmware Message B.7
- FigureC.1 Two Independent Layers of Cryptographic Security Protect the SEL3022 Wireless Operato...
- FigureC.2 Operation of the HMAC SHA-1 Keyed Hash Authentication Function C.9
- FigureC.3 Operation of the AES Encryption Function C.10
- FigureC.4 SEL3022 Security Application Overview C.11
- FigureC.5 Wireless Interface Session Authentication Dialog C.15
- Preface
- Introduction & Specifications
- Installation
- Job Done Example
- Settings and Commands
- Testing and Troubleshooting
- Firmware and Manual Versions
- Firmware Upgrade Instructions
- Wireless Operator Interface Security
- Introduction
- Wireless Interface Security Overview
- IEEE 802.11 WEP Security
- The SEL Security Application
- Certificates
- Glossary
SEL-3022 Transceiver Instruction Manual Date Code 20050615
Settings and Commands
Serial Port Settings
4.2
Cryptographic Manual—Do Not Copy
Serial Port Settings
The following settings in Tab l e 4.1 configure the serial port.
The SEL-3022 Universal Asynchronous Receiver/Transmitters (UARTs) have a one-
character receive buffer. If the SEL-3022 asserts Hardware (HW) flow control, one
additional character can be sent to the SEL-3022 without loss of data. If HW flow
control is asserted and characters are still being sent to the SEL-3022 (e.g., from the
serial port of a device connected to the SEL-3022) then characters will be lost.
Table 4.1 Settings: DCE Port
Setting Name Setting Description Value or Range
Bits Per Second Serial Port Baud Rate in
Bits per Second
300, 1200, 2400, 4800,
9600, 19200, or 38400
Data Bits Number of data bits in serial
port data format
6, 7, or 8
Parity Parity mode of the serial
port
Odd, Even, or None
Stop Bits Number of stop bits in the
serial port
1 or 2
Flow Control Selects hardware flow con-
trol
Hardware or None