User's Manual
Table Of Contents
- Table of Contents
- List of Tables
- List of Figures
- Figure1.1 Typical SEL3022 and SEL5810 Virtual Serial Software Application 1.2
- Figure1.2 Encrypted Packet Stream 1.4
- Figure1.3 Typical Connections for the SEL3022 1.6
- Figure1.4 Typical Alarm Output Installation 1.8
- Figure2.1 SEL3022 Dimension Drawing 2.2
- Figure2.2 Windows Run Command 2.3
- Figure2.3 Product Unregistered Prompt 2.4
- Figure2.4 Select a Device Type to Create 2.7
- Figure2.5 Specify New Device Location 2.8
- Figure2.6 Opening Device 2.8
- Figure2.7 Identification Screen 2.9
- Figure2.8 Status: Device 2.10
- Figure2.9 Settings: Wireless 2.10
- Figure2.10 Settings: WEP Keys 2.11
- Figure2.11 Settings: User 2.11
- Figure2.12 Settings: Operator 2.12
- Figure2.13 Settings: Security Officer 2.12
- Figure2.14 Confirm Send Prompt 2.13
- Figure2.15 Send Operation Message 2.13
- Figure2.16 Select Items to Print 2.14
- Figure2.17 Print Window 2.14
- Figure3.1 Remotely Located Recloser Control 3.2
- Figure3.2 Job Done Example SEL-5809 Top Level View 3.3
- Figure3.3 Select a Wireless Session for DNP3 Job Done Example 3.4
- Figure3.4 Settings: DCE Port 3.4
- Figure3.5 Status: Virtual Serial Port With Connection Status Red 3.5
- Figure3.6 Communication Parameters Window in acSELerator 3.6
- Figure3.7 Status: Virtual Serial Port With Connection Status Green 3.6
- Figure3.8 Reading Settings Via the SEL3022 3.7
- Figure3.9 Monitoring SEL651R Meter Data Via the SEL3022 3.8
- Figure3.10 Status: Virtual Serial Port Connection Status Red 3.9
- Figure3.11 Specify Device to Export to SEL5810 Virtual Serial Software 3.10
- Figure3.12 Export Encrypted User Configuration File 3.10
- Figure3.13 Store Encrypted File 3.11
- Figure3.14 Password Prompt in SEL5810 Virtual Serial Software 3.12
- Figure3.15 Communication Parameters Window in acSELerator 3.13
- Figure3.16 Reading SER Report Via acSELerator 3.14
- FigureB.1 PC to SEL3022 Connection B.2
- FigureB.2 SEL3022 and SEL-5809 Connection Parameters B.2
- FigureB.3 SEL5809 Settings Software Connection Method B.3
- FigureB.4 SEL-5809 Opening Connection B.3
- FigureB.5 Status: Device Window B.4
- FigureB.6 Confirmation Prompt B.4
- FigureB.7 Send Operation Prompt B.4
- FigureB.8 Configuring Serial Port Settings in the Terminal Software B.5
- FigureB.9 Send File Prompt B.6
- FigureB.10 Sending Confirmation Window B.6
- FigureB.11 Terminal Invalid Firmware Error Message B.7
- FigureB.12 Terminal Valid Firmware Message B.7
- FigureC.1 Two Independent Layers of Cryptographic Security Protect the SEL3022 Wireless Operato...
- FigureC.2 Operation of the HMAC SHA-1 Keyed Hash Authentication Function C.9
- FigureC.3 Operation of the AES Encryption Function C.10
- FigureC.4 SEL3022 Security Application Overview C.11
- FigureC.5 Wireless Interface Session Authentication Dialog C.15
- Preface
- Introduction & Specifications
- Installation
- Job Done Example
- Settings and Commands
- Testing and Troubleshooting
- Firmware and Manual Versions
- Firmware Upgrade Instructions
- Wireless Operator Interface Security
- Introduction
- Wireless Interface Security Overview
- IEEE 802.11 WEP Security
- The SEL Security Application
- Certificates
- Glossary
Date Code 20050615 Instruction Manual SEL-3022 Transceiver
Installation
Initializing the SEL-3022
2.15
Cryptographic Manual—Do Not Copy
Wireless Configuration
A wireless card is required to perform in-system settings modifications, monitoring,
and to establish a virtual serial port connection. The SEL-3022 complies with the IEEE
802.11b Wireless Standard. Suitable wireless cards and associated software drivers can
be found at your local computer or office supply store.
Follow the 802.11b manufacturer’s installation procedure (for either the PC Wireless
Card or a PDA) to install the wireless card.
After the wireless card is installed, you must enable Wired Equivalence Protocol
(WEP—see Appendix C: Wireless Operator Interface Security for details). Open the
802.11b wireless driver and locate the security settings. Enter all WEP keys, including
the active WEP key. The WEP keys on your PC or PDA must match the WEP keys the
SEL-5809 Settings Software loaded during SEL-3022 initialization.
Preliminary Copy