2. Your Safety
NOTE: Although less than 5 to 6 metres will increase extraction power this will result in higher noise
level. Maximum duct length 15 metres. Check with supplier if longer duct length is required. Do not
reduce the duct size at any time and avoid sharp bends.
Minimum Mounting Height
This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part
of the fan impeller) above a oor or the ground.
Avoidance of Back Flow
Care should be taken to avoid the back ow of gases into the room from the open ue of gas or
other open re appliances.
Safety of Children
This fan is not intended for use by young children or inrm persons without supervision.
Replacement of supply cord
If the supply cord is damaged, it must be replaced by a service agent or suitably qualied person in
order to avoid a hazard.
Why Flexi-duct
Some internet sites strongly recommend the use of rigid ducting over fully exible ducting. This may
well be the case with conventional rangehoods with internal motor rangehood but not with external
motor rangehood.
Schweigen’s unique Isodrive system works in the opposite way to conventional rangehoods, pulling
air through the hood and acoustically matched ducting, producing almost silent high volume ow.
The use of a complete rigid or semi-rigid ducting system will allow an organ piping effect to occur;
like a didgeridoo where a noise is produced at one end of a hollow rigid pipe and the noise is
amplied out the other.
The Isodrive system places the noise outside the house and it needs to be kept there.
WARNING: Installation without the use of at least the minimum recommended length of acoustically
matched exi-ducting in the system will void performance expectations. Any installation problem
must be reported to Schweigen. Call outs relating to incorrect installation will result in a service fee
direct to the customer. Schweigen takes no responsibility for problems caused by faulty installation,
this may void warranty. A preferred installer list can be obtained from Schweigen website
www.schweigen.com.au or by calling 1300 881 693.