Installation Guide

Page 5
2. Your Safety
This guide is for the installation of the Isodrive motor system after the canopy/rangehood or bathroom
extraction grill has been mounted on the wall or ceiling. (Refer to canopy/rangehood or bathroom
extraction unit installation manual).
NOTE: All PVC pipe and exi ducting measurements are referring to inside measurements, unless
otherwise mentioned.
Motor Features
Roof and wall mounting with IPX4 degree of weather protection.
Super quiet, long vane, backward curved centrifugal fan.
Airow is dependant on installation and the ducting used. Using single 200mm ex duct, you
should attain up to 1600m
3
/hr. The use of a smaller than 150mm (ISD) pipe would result in a loss of
airow.
Simple installation: mounts onto a 150mm PVC pipe for ultimate strength and allows for easy
Dektite roof sealing.
Industrial quality motor and fan made in Germany and rated at 40,000 hours.
Motor is a high efciency PSC type and rated at 135W costing around the same as two 70W light
globes to run.
WARRANTY 10 YEARS return to manufacturer. Covers faulty manufacturing or components. It does
not cover normal wear and tear.
General Notes on Installation and Use
This fan unit is designed to be installed using 150mm (ISD) PVC pipe as the initial connection duct to
the fan module, and is supplied with a 150mm (ISD) PVC pipe to 200mm (ISD) exible duct
bell-mouth adaptor.
This fan is suitable for connection to multiple duct runs with a minimum inlet area of 22,000mm
2
and
length up to 15 metres maximum (check with supplier if longer duct length required). Where possible
exible ducting must be extended sufciently to present a smooth air passage with bends of at least
the radii of twice the diameter of the duct.
WARNING: The rangehood must not be ducted into a wall cavity or a ceiling space, where a build
up of grease can occur and become a potential re risk. This will void warranty.
NOTE: Fan module and dual foil exi-duct are acoustically matched. Use of semi-rigid or rigid ducting
will result in increased noise and may void warranty. See installation instruction notes ‘Why exi-duct’.
Recommended Installation Distance
Isodrive 1600 motor, recommended 5 to 6 metres of exi ducting.