INSTALLATION GUIDE Isodrive 3200 Revision V1.1 HOME APPLIANCES www.schweigen.com.
Index 1. Welcome _____________________________________________________________________________________________________ 3 2.
1. Welcome Thank you for purchasing your new Schweigen Isodrive system. To get the maximum output from this unit, please read through this operating guide before use and installation. The operating guide contains important information on the correct use and maintenance of the unit, as well as important safety notes. This will ensure your personal safety and the lasting value of your Isodrive system. We trust that you will enjoy your new Schweigen Isodrive system.
2. Your Safety WARNING Please read this section thoroughly before attempting to operate the appliance. Inspect your product upon receipt. Any damage or defects MUST be reported within 48 hours, or no claim will be recognised. DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED. If this product is installed damaged, neither the supplier, nor the retailer, will be responsible for the costs associated with the repair, replacement, removal or re-installation of the appliances.
2. Your Safety This guide is for the installation of the Isodrive motor system after the canopy/rangehood has been mounted on the wall or ceiling. (Refer to canopy/rangehood unit installation manual). NOTE: All PVC pipe and flexi ducting measurements are referring to inside measurements, unless otherwise mentioned. Motor Features • Roof and wall mounting with IPX4 degree of weather protection. • Super quiet, long vane, backward curved centrifugal fan.
2. Your Safety Minimum Mounting Height This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the fan impeller) above a floor or the ground. Avoidance of Back Flow Care should be taken to avoid the back flow of gases into the room from the open flue of gas or other open fire appliances. Safety of Children This fan is not intended for use by young children or infirm persons without supervision.
3. Description Isodrive Motor 1 Included in the box: 1. Isodrive 3200 motor (450W x 290H mm approx.) Approx. 3 metre, 10amp cable and standard male plug Power Cord 50mm 250mm PVC Pipe Dektite Fix pipe to fan module with side locking screws 2. Fire resistant 250mm OD PVC riser pipe Note: Cable cut-out at the both ends 1 3. Flexible ducting (250mm) Approx.
4.
4. Installation Roof Installation Recommended duct length: minimum 4 metres. Mount 250mm (ISD) rigid PVC pipe securely to beams, trusses or other appropriate structures: refer figure 1. The pipe should be mounted vertically with the roof penetration being sealed using a Dektite or other appropriate sealing membrane or device. Ensure that the PVC pipe protrudes at least 50mm past the top of the Dektite, checking that the fan assembly clears the roof cladding at upper edge, refer figure 1.
4. Installation THROUGH WALL INSTALLATION Through Wall Installation Minimum portrusion distance from wall Recommended to fix pipe to a support Connecting pipe structure or strapping bracket (not included in mounting kit). Wall Power cable Mounting points Ensure power cable, pipe and Wall cover plate cover plate slot is at the bottom. (Optional - Part Number P2025) Note: Make sure that the connecting pipe is well supported, at least 2 mounting points recommended.
4. Installation Protrude pipe to distance (use as reference only) Mounting points Marked fastening holes first before installing Ensure slot cover plate, power cable and pipe slot Fix pipe to structure or with a strapping bracket. is at the bottom.
4. Installation Twin 200mm Outlet Installation Example (3200 Kit required) This is for use where one motor is to be used and there are two 200mm outlets. 3200 motor Ensure flexible ducting is fully extended and as short as possible. Use smooth flowing curves for maximum air flow. Remove excess ducting by trimming to length. 250 x 200 x 200mm If multi-fit Y joint supplied you will need to cut to size.
5. Measurements Measurements for Isodrive 3200 (Not to Scale) Dimensions in mm 288 400 342 440 15.7 50 Isodrive 3200 weighs 8.3 kg without the PVC pipe. 250.
6. Flexible Duct Flexible Ducting Flexible ducting must be fully extended and cut to the required length upon installation. Maximum fan performance will not be achieved unless the ducting is fully extended. Failure to fully extend ducting results in a smaller air passage and lower airflows. Incorrect installation may reduce airflow or increase noise levels. Call outs relating to incorrect installation will result in a service fee directed to the customer.
6. Flexible Duct Shallow Roof Space In shallow roof spaces, do not crush or kink flexible ducting, as it will reduce air flow severely. 90 degree curve made of PVC or galvanise can be used as a substitute for the bend, refer to figure 5. 90 degree curve PVC or galvanise curve Figure 5 Important Note Please do not crush or kink flexible ducting, as it will reduce air flow and may cause noise to occur through the system. Ducting needs to be kept taut at all times.
6. Flexible Duct Securing Flexible Duct Flexible duct must be installed with supports at maximum intervals of 1.5 metres. Flexible ductwork can be supported by using gaffer or electrical tape. Provided that it does not restrict the internal diameter of the ducting. Ducting installed looped over hanging beams should be installed in such a manner as to ensure the changes of direction are gradual. Support of the ducting with the use of hangers may be required, see option 2.
7.
7. Parts List Parts List for Isodrive 3200 Page 18 Number Part Number Description Quantity 1 P1114 Capacitor 4µF 1 2 P1123 No.6 X 1 ¼ “ S/T Screw Pan Head 1 3 P40112 Terminal Box – Box Base and Lid 1 4 P807 Terminal Block 1 5 P1122 No.
8. Maintenance Roof Restoration or Cleaning Before doing your roof restoration or cleaning, please completely cover the outside motor system and avoid all chemical contact. IMPORANT Any damages caused by the use of chemical products are not covered by warranty. Figure 9 Avoid chemical contact to motor system. **Images for illustration purposes only. Applies for all motors. Warranty (See warranty for more information) Isodrive motor has a 10-Year replacement product warranty.
HOME APPLIANCES Distributed by: Unit 102/45 Gilby Road, Mt Waverley 3149 Victoria. 1300 881 693 (EST) www.schweigen.com.