RANGEHOOD & INSTALLATION GUIDE CL7272S Revision V2 03/11/20 www.schweigen.com.
Index 1. Welcome Your State Regulatory Authority 3 3 2. Important Safety Information Before Installation Product Use Ducted or Recirculating? Maintenance and Service Cleaning the Baffle Filters Electrical Cord 4 5 6 6 6 6 6 3. Description Rangehood 7 7 4. Operation Push Button Control Panel Speed Control 8 8 8 5. Cleaning & Maintenance Surfaces Filters Cleaning the Interior Cleaning the Exterior Replacing the Light Bulb 9 9 9 10 10 11 6.
1. Welcome Thank you for purchasing your new Schweigen rangehood. To get the maximum output from this unit, please read through this guide before use. The guide contains important information on the use and maintenance of the unit, as well as important safety notes. This will ensure your personal safety and the lasting value of your rangehood. We trust that you will enjoy your new Schweigen rangehood. Please always retain your proof of purchase to aid in any warranty queries.
2. Important Safety Information WARNING Please read this section thoroughly before attempting to operate the appliance. Inspect your product upon receipt. Any damage or defects MUST be reported within 48 hours, or no claim will be recognised. DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED. If this product is installed damaged, neither the supplier, nor the retailer, will be responsible for the costs associated with the repair, replacement, removal or re-installation of the appliances. 1.
2. Important Safety Information 18. It is forbidden to use the rangehood as an aspirator. 19. Never cook foodstuff directly over the flame or have the gas burners on under the rangehood without using cookware. Before Installation 1. We recommend this appliance be installed or repaired by a qualified Schweigen Home Appliances technician. 2. Please see our website www.schweigen.com.au for recommended installers. 3. It is dangerous to modify any part of this appliance.
2. Important Safety Information Product Use This product is designed for household use and should not be used for commercial applications. After use, always ensure that all controls are in the “OFF” position. When frying with a gas flame, take particular care not to allow the oil or grease in the pan to catch fire. (Flambé) Ducted or Recirculating? Ducted rangehoods (or extractor rangehoods) extract the cooking fumes from the kitchen and expel them from the space via ducting.
3. Description Rangehood 1 1. Mounting Bracket 2. Upper Flue 3. Lower Flue 2 4. For use with Isodrive motor system ® 5. Power Cord 3 6. Rangehood Body 7. Baffle Filters 8. Lights 4 5 6 NOTE: Filter and light quantity may vary from model to model.
4. Operation Push Button Control Panel Turn off the rangehood Low speed setting Medium speed setting High speed setting Turn on/off the lamp Speed Control This undermount is equipped with a 3 speed mechanical control. Speed control usage suggestions: • Low speed for simmering. • Medium speed for light cooking. • High speed for heavy frying or heavy cooking.
5. Cleaning & Maintenance Warning Always switch off and disconnect power before cleaning. Cleaning the Interior Clean the interior of the rangehood with a damp cloth and a neutral detergent or denatured alcohol. NOTE: Do not use denatured alcohol on the exterior of the rangehood. Do not clean the electric parts or the motor with liquids or solvents Cleaning the Exterior We recommended using a soft cloth, water and a liquid soap, rinsing it well and then drying it thoroughly.
5. Cleaning & Maintenance Baffles For this appliance to function effectively, regular maintenance is a must. • The function of the baffle is to collect the grease particles given off during cooking. • Clogged heavy oil deposits restrict airflow and may cause the motor to overheat and become a fire hazard. • Baffles should be cleaned every 3-6 weeks or after 40 hours of use. • For induction cooktop, please aim to clean them at least every 10 days, depending on use.
5. Cleaning & Maintenance Replacing the Light Bulb Danger Always switch off and disconnect the power cord before replacing any light bulbs. Failure to do so may cause serious injury. Please be aware that the light bulb will retain heat for a short period of time after being switched off. Step 1 Step 2 Step 3 Remove the filters from the rangehood. Gently turn light bulb clockwise, pull the light bulb down and remove it from the light holder.
6. Installation Rangehood Size vs Cooktop Size In addition to the size, the height of the rangehood above the cooktop is important to obtain the best performance. INADEQUATE Rangehood smaller than cooking zone ADEQUATE Rangehood same size as cooking zone OPTIMAL Rangehood larger than cooking zone BBQ Installation When installing the rangehood over a BBQ , please be aware that the lid will obstruct the rangehoods effectiveness to extract smoke, steam and odours.
_n_. _RH 6. Installation Section_ Mounting Instructions – Outdoor/Alfresco When installing in an outdoor kitchen or alfresco area,the rangehood MUST NOT be installed where it is directly exposed to the elements . It is STRONGLY RECOMMENDED that the rangehood be installed centrally over the cooktop. This will greatly improve its performance. Minimum legal height from the BBQ surface to the underside face of the rangehood: • 1200mm Any installation above 1200mm will compromise the extraction performance.
6. _n_. Installation _LH Section_ Wall Mount Installation There are two primary mounting points and several secondary mounting points to firmly fix the rangehood in place. Suitable fixing screws must be used to mount the appliance on a secure surface. Please ensure that the holes for the two primary mounting points are level before installation. 1. Primary Mounting Points 2. Secondary Mounting Points 780 721 1 240 1 750 540.25 2 540.25 2 2 WARNING Please remove filters before installation.
_n_. _RH 6. Installation Section_ Step 1 Secure rangehood to the wall using only primary mounting points ( 1 ). Check the level of the rangehood and adjust accordingly if necessary ( 2 ). Once level, continue to secure the rangehood via the secondary mounting points ( 3 ). Step 2 Feed through and secure the flexi ducting from the rangehood outlet to the Isodrive motor.
6. Installation Step 3 2 2 Place flue covers on the rangehood and extend to the length required. (Be careful not to scratch the top of the rangehood). PLEASE NOTE: Only a standard length of stainless steel flue is provided. Any additional length will need to be sourced and manufactured by a sheet metal fabricator. Step 4 Attach the exterior flue wall mounting bracket to the wall. Slide the inside extension flue piece up to the wall mounting bracket and secure.
6. Installation Ducting Please DO NOT crush or kink the ducting. 1. Crushed or kinked ducting creates sharp corners that creates turbulence. This reduces the size and efficiency of the ducting, lowers extraction and may cause excessive noise. 2. Sweeping curves and taut ducting reduces resistance and turbulence. The airflow and extraction will be more efficient and stronger.
6. Installation Isodrive® Motor Setup Note Please refer to the Isodrive® motor installation guide for more details on flexi ducting and Isodrive® motor installation. Important Please remove the clip when attaching Isodrive® 1600 / 3200 motor (Single or Twin) system. To remove the clip, hold down 1, 2 and 3 gently pull out to direction 4. NOTE: DO NOT REMOVE the clip at the end of the white cord when installing an Isodrive® 650 / 900 motor (Single or Twin) system.
6. Installation Single Isodrive® Motor Installation 1. Isodrive® Motor 1 2. Roof Seal Kit (Dektite) (Not supplied)* 2 3. Support Straps (Not supplied)* 3 4. Attach Flexi Duct to Bell-Mouth Adaptor using ring clamp. Please DO NOT rip the ducting. 4 200mm Flexi Duct 5 200mm Flexi Duct 5. Isodrive® Motor Power Lead (Male Plug) 6. Rangehood to Isodrive® Motor Lead (Female Plug) 7 7. Multi-fit Y-Joint, cut to 200 x 200 x 200mm 6 8 9 10 8. Mains power 9. Flexi Ducting must be pulled taut.
6. Installation Twin Isodrive® Motor Installation 1. Isodrive® Motors 2. Roof Seal Kit (Dektite) (Not supplied)* 1 3. Support Straps (Not supplied)* 3 2 4. Attach Flexi Duct to Bell-Mouth Adaptor using ring clamp. Please DO NOT rip the ducting. 4 5 5. Isodrive® Motor Power Lead (Male Plug) 6. Rangehood to Isodrive® Motor Lead (Female Plug) 6 7 8 8 9 7. Mains power 8. Flexi Ducting must be pulled taut. DO NOT crush or kink the ducting. 9.
6. Installation Optional Wall Mounted Motor Installation The Isodrive motor can optionally be installed mounted to a wall if a roof mount is not possible. The construction of a bulkhead is also recommended. The position of the motor can be to an external wall as shown above, or to the same external wall as the rangehood is mounted, as shown below. For all wall installation options, please refer to the Isodrive® Motor manual. Avoid sharp bends and kinked ducting as this will affect extraction performance.
Please make sure there is no obstruction in ducting or with the back draft fins. Check the outlet, make sure it is not blocked and you have the correct diameter ducting installed. X X X Rangehood does not direct air out (through chimney) X X Rangehood does not work X X Light does not work X Loud noise from the rangehood Page 22 X X X X Check the ducting has not come off the rangehood outlet or has been eaten through by rodents.
7. Troubleshooting Service Lodging an Online Service Request In the event that the failure is not due to the faults mentioned in the Troubleshooting section, you can lodge an online Service Request. To lodge an online Service Request, visit our website www.schweigen. com.au/service-and-warranty and click on the link and complete the service request form. A service request will require the following information: • The purchase date • The rangehood model and motor type (e.g.
8. Specifications Dimensions 350 795 550 1240 600 352 797 120 1200 700 Technical Specifications Model CL7272S Feeding Voltage 220–240V 50Hz Lamp Power — LED (W) 3 x 3.
9. Disclaimer Disclaimer Under our policy of continuous product development, product specifications may change without notice. Prospective purchasers should therefore check with the retailer to ensure this publication correctly describes the products being offered for sale.
Notes Page 26
Notes Page 27
Australia 8/3-4 Anzed Court, Mulgrave 3170 Victoria. Phone 1300 881 693 Email sales@schweigen.com.au Web www.schweigen.com.au New Zealand 5 Tolich Place, Henderson, Auckland 0610. Phone 0800 200 510 Email info.parex@emerson.com Web www.parex.co.