Owner`s manual
GP-MSJW-CX-07B
STW-JZ / IW Manual
RD: Sept, 2005
RL: 7B
KH
FIGURE 1 MINIMUM CLEARANCES TO COMBUSTIBLES
TABLE 3 MINIMUM CLEARANCES TO COMBUSTIBLES
MODEL
SUSPENDED AT AN ANGLE
UP TO 45 DEGREES
SUSPENDED
HORIZONTALLY
D E F G A B C
STW-JZ / IW-200 6” 1” 57” 68” 6.5” 22” 68”
STW-JZ / IW-175 4.5” 1” 47” 68” 5.5” 20” 68”
STW-JZ / IW-155 3.5” 1” 44” 64” 5.5” 19” 64”
STW-JZ / IW-130 3.3” 1” 35” 56” 4.5” 11” 60”
STW-JZ / IW-110 2” 1” 26” 54” 3.5” 10” 54”
STW-JZ / IW-80 1.75” 1” 23” 38” 3” 6.0” 36”
STW-JZ / IW-60 1.5” 1” 17” 34” 2.5” 5.5” 34”
STW-JZ / IW-45 2.25” 1” 24” 32” 2.75 7” 32”
The clearances to combustibles are established at points reaching a surface temperature of 160
0
F.
Some materials such as awnings or plastic may require higher distances. Respect clearances as shown
D
F
A
B
E
G
C
B
Page 5