Owner`s manual
7
S100 / ITB I&O Manual
IM090513
RD: MAY 2009
RL: 04A - BA
TABLE 1 MINIMUM CLEARANCES TO COMBUSTIBLES*
FIGURE 1 MINIMUM CLEARANCES TO COMBUSTIBLES* - refer to Table 1 for values
*NOTE: Clearances are measured from the reflector
.
The clearance to combustible materials represents the minimum distance that must be main-
tained between the heater and a nearby surface. The stated clearance to combustibles
represents a surface temperature of 90F° (50C°) above room temperature. continued ...
NOTE: A ‘PEEL & STICK’ SIGN IS SUPPLIED: USE AN INDELIBLE MARKER TO
ENTER VALUES ‘H’, ‘S’, ‘F’, & ‘B’ ON .
POST THE SIGN ADJACENT TO THE HEATER THERMOSTAT OR IN A
PROMINENT LOCATION.
See next page for details.
F
D
B
A
S
S
C
Suspended at an
angle up to 45°
Suspended
horizontally
C
FLOOR
H
T
H
Maximum
Stack Height
H = T- C
‘T’ is meas-
ured on site,
FLOOR
T
Maximum
Stack Height
H = T- C
‘T’ is meas-
ured on site,
MODEL
Both “Straight”
& “U-Tube”
HORIZONTAL ANGLE UP TO 45 DEGREES
TOP SIDE BELOW TOP REAR FRONT BELOW
A
inches (cm)
S
inches (cm)
C
inches (cm)
D
inches (cm)
B
inches (cm)
F
inches (cm)
C
inches (cm)
S100 / ITB 200 7” (18) 22” (56) 68” (172) 7” (18) 1” (2.5) 57” (145) 68” (172)
S100 / ITB 175 6.5” (16.5) 20” (51) 68” (172) 6.5” (16.5) 1” (2.5) 47” (119) 68” (172)
S100 / ITB 155 6” (15) 19” (48) 64” (163) 6” (15) 1” (2.5) 44” (112) 64” (163)
S100 / ITB 130 4” (10) 11” (28) 60” (152) 5” (13) 1” (2.5) 35” (89) 56” (142)
S100 / ITB 110 3” (8) 10” (25) 60” (152) 4.5” (11) 1” (2.5) 26” (66) 54” (137)
S100 / ITB 80 2.5” (6) 6” (15) 42” (107) 3.5” (9) 1” (2.5) 23” (59) 38” (97)
S100 / ITB 60 2.5” (6) 5.5” (14) 34” (86) 3” (8) 1” (2.5) 17” (43) 34” (86)
S100 / ITB 100 7” (18) 22” (56) 68” (172) 7” (18) 1” (2.5) 57” (145) 68” (172)
S100 / ITB 45 4.5” (11) 8.5” (22) 32” (81) 5” (13) 1” (2.5) 29” (74) 32” (81)