Version 005 infra_calor D shape U Australia 42/14 Technical specification subject to change
Fig. 24: Connecting diagram single-stage regulation infraSchwank D / calorSchwank D
Fig. 25: Connecting diagram two-stage regulation infraSchwank D / calorSchwank D
Burner
unit
Control box
Thermocontrol Plus M /
unoSchwank
L
N
PE
L
N
PE
Gas valve VK 4105C
Electrical supply 1~230Volt, 50Hz, N, PE
1
2
PE
single-stage operation
Gas valve VK4115Q / VK 4105Q
with lifting magnet 2-stage
Burner
unit
Time delay 1minute
ignition for max. load
(integrated in control box
duoSchwank
and Thermocontrol Plus M
)
Control box
Thermocontrol Plus M /
duoSchwank
L1
N
PE
L1
L2
N
PE
Connection box
Electrical supply 1~230Volt, 50Hz, N, PE
1
2
PE
two-stage operation