ft [m] ft [m] ft [m] ft [m]
ft
2
[m
2
] watts / ft
2
Min. 7 [2.1] 8.8 [2.7] 8.5 [2.6] 16 [4.9] 108 [10.1] 13.9
Max. 8 [2.4] 9.8 [3.0] 9.2 [2.8] 18 [5.5] 133 [12.4] 11.3
Min. 8 [2.4] 9.8 [3.0] 9.2 [2.8] 18 [5.5] 133 [12.4] 15.0
Max. 9 [2.7] 11 [3.4] 10 [3.0] 20 [6.1] 165 [15.3] 12.1
Min. 10 [3.0] 12 [3.6] 11.2 [3.4] 23 [7.0] 205 [19.0] 19.5
Max. 11.5 [3.5] 13.5 [4.1] 14 [4.3] 27.5 [8.4] 275 [25.4] 14.5
Min. 12 [3.7] 14 [4.3] 15 [4.6] 29.5 [9.0] 315 [29.2] 19.0
Max. 15 [4.6] 14.4 [4.4] 17.7 [5.4] 32 [9.8] 360 [33.4] 16.7
IEP 6024 6000
IEP 1520/4 1500
IEP 2024
E
A
verage Heat
Density
IEP 4024 4000
D
Heated
Area
2000
C
Outer
Perimeter
Distance
Out
B
Under
Heater
Min /
Max
Input
Watts
Model
.
H
Height Above
Floor/Deck
FIGURE 1: RECOMMENDED MOUNTING: COMFORT AREA COVERAGE
TABLE 1: RECOMMENDED MOUNTING FOR SAFETY AND COMFORT AREA COVERAGE
Angle of Heat Dispersion
The design information presented here is intended as a guideline. The accuracy of determin-
ing or estimating all factors above will affect performance and satisfaction. Air movement in
particular affects creature comfort.
 Refer to design guidelines on previous page.
 Refer to Required Minimum Clearances: Table 2 & Figure 2, Page 10