Datasheet
6
3-Phasen AC-Filter / DC-Filter
FMBC NEO
www.schurter.com/pg80
EMV Produkte
Technische Angaben zu den Filterkomponenten
Bemessungsstrom
@ Tu 50°C (75°C) [A]
L [mH] L1 [μH] C1 [μF] C2 [μF] C3 [μF] R1 [MΩ] R2 [MΩ] R3 [MΩ]
7 (4.7) 2.7 5 3.3 3.3 3.3 - 1 1
16 (12) 1.9 10 6.6 3.3 3.3 1 1 1
30 (21) 1.9 10 6.8 3.3 3.3 1 1 1
42 (31) 1.3 10 9.9 3.3 3.3 1 1 1
55 (49) 1.8 13 10 3.3 3.3 1 1 1
75 (52) 1.2 13 9.9 3.3 3.3 1 1 1
100 (70) 1.2 13 9.9 3.3 3.3 1 1 1
130 (92) 0.7 26 9.9 3.3 3.3 1 1 1
180 (135) 0.4 31 10 3.3 3.3 1 1 1
7 (4.7) 2.7 5 3.3 3.3 3.3 - 1 1
16 (12) 1.9 10 6.6 3.3 3.3 1 1 1
30 (21) 1.9 10 6.8 3.3 3.3 1 1 1
42 (31) 1.3 10 9.9 3.3 3.3 1 1 1
55 (49) 1.8 13 10 3.3 3.3 1 1 1
75 (52) 1.2 13 9.9 3.3 3.3 1 1 1
100 (70) 1.2 13 9.9 3.3 3.3 1 1 1
130 (92) 0.7 26 9.9 3.3 3.3 1 1 1
180 (135) 0.4 31 10 3.3 3.3 1 1 1
Schaltbilder
1)
L
C1
C1
C1
R1
R1
R1
L1
L2
L3
PE
L1'
L2'
L3'
PE
1
C2
C2
C2
R2
R2
R2
R3
C3
L
1) Netz
Derating Kurven
Zulässiger Nennstrom (im Quadrat) als Funktion der Temperatur
Zul. Betriebsstrom in % des In
100
80
60
40
20
0
0 20 40 60 75 100
UL Listed
Umgebungstemperatur Tu in °C