Datasheet
2
Non resettable fuses
172593
www.schurter.com /PG01_2
Fuses
Time-Current-Curves
Time in Seconds
0.001
0.01
0.1
1
10
100
1000
10000
100000
1
10
Multiple of Rated Current In
All Variants
Rated Cur-
rent [A]
Rated Vol-
tage [VAC]
Rated Vol-
tage [VDC]
Breaking
Capacity
Voltage Drop
1.0 In typ.
[mV]
Melting I²t
10.0 Intyp.
[A²s]
Order Number
0.05 250 125 1) 1150 0.00011
l
7010.1740.46
0.063 250 125 1) 735 0.00035
l
7010.1750.46
0.08 250 125 1) 950 0.00039
l
7010.1760.12
0.1 250 125 1) 875 0.00079
l
7010.1770.12
0.1 250 125 1) 875 0.00079
l
7010.1770.46
0.125 250 125 1) 870 0.0013
l
7010.1780.12
0.125 250 125 1) 870 0.0013
l
7010.1780.46
0.15 250 125 1) 545 0.0029
l
7010.1790.12
0.15 250 125 1) 545 0.0029
l
7010.1790.46
0.2 250 125 1) 520 0.0071
l
7010.1910.12
0.2 250 125 1) 520 0.0071
l
7010.1910.46
0.3 250 125 1) 920 0.021
l
7010.1920.12
0.3 250 125 1) 920 0.021
l
7010.1920.46
0.4 250 125 1) 725 0.057
l
7010.1930.12
0.4 250 125 1) 725 0.057
l
7010.1930.46
0.5 250 125 1) 725 0.069
l
7010.1800.46
0.6 250 125 1) 205 0.059
l
7010.1810.12
0.6 250 125 1) 205 0.059
l
7010.1810.46
0.8 250 125 1) 150 0.095
l
7010.1820.12
0.8 250 125 1) 150 0.095
l
7010.1820.46
1 250 125 1) 185 0.12
l
7010.1830.46
1.25 250 125 1) 125 0.29
l
7010.1840.12
1.25 250 125 1) 125 0.29
l
7010.1840.46
1.6 250 125 1) 135 0.48
l
7010.1850.12
1.6 250 125 1) 135 0.48
l
7010.1850.46
2 250 125 1) 110 0.95
l
7010.1860.12
2 250 125 1) 110 0.95
l
7010.1860.46
2.5 250 125 1) 145 1.2
l
7010.1870.12