Datasheet
Table Of Contents

4
Fuses
UMK 250
https://www.schurter.com /PG01_2
Fuses
Rated Cur-
rent [A]
Rated Vol
-
tage [VAC]
Rated Vol
-
tage [VDC]
Breaking
Capacity
Voltage Drop
1.0 In max.
[mV]
Voltage Drop
1.0 In typ.
[mV]
Power Dissi
-
pation 1.25 In
max [mW]
Melting I²t
10.0 In typ.
[A²s]
Order Number
UMK 250 = UMF 250 (Au) + UMC 250
There is no approval existing for the combination fuse and clip UMK 250, but the fuse and the clip are fully approved independently at VDE/UL. See
details above.
In the reflow soldering process, the fuse must have gold-plated caps, otherwise fuse and clip would be soldered together. For fuse replacement in the
field, a standard UMF 250 fuse with tin-plated caps can be used.
It is not allowed to replace higher rated current than 4 A in the clip.
Packaging Unit
.xx = .11 Blister Tape (100 pcs.)
.xx = .22 Blister Tape 33 cm Reel (1000 pcs.)
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
02.07.2018