Datasheet

2
Non resettable fuses
OMT
www.schurter.com/PG01_2
Fuses
Pre-Arcing Time
Rated Current In 1.0 x In min. 2.0 x In min. 2.0 x In max. 3.0 x In min. 3.0 x In max. 8.0 x In min. 8.0 x In max.
0.75 A - 5 A 4 h 100 ms 60 s 70 ms 3 s 5 ms 50 ms
Variants
Rated Cur-
rent [A]
Rated Vol-
tage [VAC]
Rated Vol-
tage [VDC]
Breaking
Capacity
Voltage Drop
1.0 In typ.
[mV]
Power Dissi-
pation 1.0 I
n
typ. [mW]
Melting t 8.0
In typ. [A²s]
Order Number
0.75 250 125 VDC 1) 200 150 0.36
l
3403.0129.xx
1 250 125 VDC 1) 146 146 0.99
l
3403.0116.xx
1.25 250 125 VDC 1) 89 111 1
l
3403.0117.xx
1.5 250 125 VDC 2) 74 111 2
l
3403.0130.xx
2 250 125 VDC 2) 69 138 4
l
3403.0119.xx
2.5 125 125 VDC 3) 68 170 7
l
3403.0120.xx
3 125 125 VDC 3) 62 186 12
l
3403.0131.xx
3.5 125 125 VDC 3) 60 210 19
l
3403.0132.xx
4 125 125 VDC 3) 60 240 23
l
3403.0122.xx
5 125 125 VDC 3) 57 285 37
l
3403.0123.xx
1) 100 A @ 250 VAC / 100 A @ 125 VDC
2) 50 A @ 250 VAC / 100 A @ 125 VAC / 100 A @ 125 VDC
3) 100 A @ 125 VAC / 100 A @ 125 VDC
Packaging Unit
.xx = .11 Plastic Bag (100 pcs.)
.xx = .24 Blister Tape 33 cm Reel (2000 pcs.)
Time-Current-Curves
Time in Seconds
0.001
0.01
0.1
1
10
100
1000
10000
100000
1
10
Multiple of Rated Current In
The specifications, descriptions and illustrations indicated in this document are based on
current information. All content is subject to modifications and amendments.
24.08.2013