Owner`s manual
•10•
TROUBLESHOOTING15.
PROBLEM POSSIBLE CAUSE REASON/SOLUTION
Noreadingontheammeter. Chargerisnotpluggedin.
Nopoweratthereceptacle.
Clipsarenotmakingagood
connectiontothebattery.
Connectionsarereversed.
Batteryisdefective(willnot
acceptacharge).
2ampchargerateisbeing
used.
PlugthechargerintoanAC
outlet.
Checkforopenfuseorcircuit
breakersupplyingACoutlet.
Checkforpoorconnectionto
batteryandframe.Makesure
connectionpointsareclean.
Rockclipsbackandforthfor
abetterconnection.
Unplugthechargerand
reversetheclips.
Havebatterychecked.
Ammetermayshowno
activityatthe2Achargerate.
Ammeterreadingstayshigh. Batteryisseverely
discharged.
Wrongbatteryvoltage.
Continuechargingbatteryfor
twomorehours.Ifproblem
continueshavethebattery
checked.
Verifythevoltagesettingson
thechargerarecorrect.
Chargerwillnotturnon
whenproperlyconnected.
ACoutletisdead.
Poorelectricalconnection.
Checkforopenfuseorcircuit
breakersupplyingACoutlet.
Checkpowercordand
extensioncordforloosetting
plug.
Thebatteryisconnectedand
thechargerison,butisnot
charging.
Clipsarenotmakingagood
connection.
Checkforpoorconnectionat
batteryandframe.Makesure
connectingpointsareclean.
Rockclipsbackandforthfor
abetterconnection.
Themeasuredcurrentis
muchlowerthanwhatwas
selected.
Thechargerreachedthe
maximumvoltageandis
reducingthecurrent.
Noproblem,thisisanormal
condition.
Ammeterreadslessthan
selectedchargeratewhen
chargingadischarged
battery
Extensioncordistoolongor
wiregaugeistoosmall.
Weakcellorsulfatedplatein
battery.
Batteryisonlypartially
discharged.
Useashorterorheavier
gaugeextensioncord.
Asulfatedbatterywill
eventuallytakeanormal
chargeifleftconnected.Ifthe
batterywillnottakeacharge,
haveitchecked.
Continuetochargethe
battery.