Datasheet
2
12-2017, Rev. 1217
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
SCHRACK
General Purpose
RT-iPower
Power PCB Relay RT Inrush Power (Continued)
Insulation Data
Initial dielectric strength
between open contacts 1250V
rms
between contact and coil 5000V
rms
Clearance/creepage
between contact and coil ≥10/10mm
Material group of insulation parts IIIa
Tracking index of relay base PTI 250V
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature RT.3T / RTS3L
monostable DC coil -40 to 105°C
bistable 1 coil -10 to 105°C
bistable 2 coils -40 to 105°C
Ambient temperature RTSET
monostable DC coil -40 to 85°C
bistable 1 coil -10 to 85°C
bistable 2 coils -40 to 85°C
RT.3T / RTSET RTS3L
Category of environmental protection
IEC 61810 RTII - flux proof
RTIII - wash tight available upon request
Vibration resistance (functional), 10g 20g
monostable version
Shock resistance (destructive) 100g
Terminal type PCB-THT, plug-in
2)
Weight, without / with test tab 14/16g 14g/-
Resistance to soldering heat THT
IEC 60068-2-20 270°C/10s
RT.3T / RTSET RTS3L
Packaging/unit
without test tab tube/20 pcs., tube/20 pcs.,
box/500 pcs. box/500 pcs.
with test tab tray/25 pcs., -
box/100 pcs. -
2) RTT3T or bistable 2 coil version: PCB mounting only. See Accessories.
Accessories RTS.
For details see datasheet
Accessories Industrial Power Relay RT
Socket available for 1 coil version only.
NOTE: indicated contact ratings and electrical endurance data for direct
wiring of relays (according IEC 61810-1); for relays mounted on sockets
deratings may apply.
Coil Data (continued),
bistable coils 1 coil 2 coils
Magnetic system polarized, bistable
Coil voltage range 3 to 24VDC
Operative range, IEC 61810 2
Limiting voltage, % of rated coil voltage 120% 150%
Min./Max. energization duration 30ms/1min at <10% duty factor
Coil insulation system according UL1446 class F
Coil Data RT.3T RTS3L
Coil versions, bistable
Coil Rated Set Reset Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% mW
Coil versions, bistable 1 coil
A03 3 2.1 1.7 21 429
A12 12 8.4 6.6 360 400
A24 24 16.8 13.2 1440 400
Coil versions, bistable 2 coils
F03 3 2.1 1.7 15 600
F12 12 8.4 6.6 240 600
F24 24 16.8 13.2 886 650
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Coil Data RTSET
Coil versions, bistable
Coil Rated Set Reset Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% mW
Coil versions, bistable 1 coil
A03 3 2.1 1.8 21 429
A12 12 8.4 7.2 360 400
A24 24 16.8 14.4 1440 400
Coil versions, bistable 2 coils
F03 3 2.1 1.8 15 600
F12 12 8.4 7.2 240 600
F24 24 16.8 14.4 886 650
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Bistable coils - operation
Version 1 coil 2 coils
Coil terminals A1 A2 A1 A3 A2
Operate + - + -
Reset - + - +
Contact position not defined at delivery