Power PCB Relay RP II/2
2 pole 8 A
Contact data
Configuration 2 C/O contact or 2 N/O contact
Type of contact single contact
Rated current 8 A (UL: 10 A)
Rated voltage / max.breaking voltage AC 250 Vac / 440 Vac
Maximum breaking capacity AC 2000 VA
Make current (max. 4 s at duty cycle 10%) 14 A
Contact material AgNi 0.15, AgCdO
Features
• 2 C/O or 2 N/O contacts
• 4 kV / 8 mm coil-contact
• Twin contacts available
• PCB-sockets
Applications
Domestic appliances, UPS's
VZ H
Technical data of approved types on request
Contact ratings
Type Load Operations Standard
RP440 64 A ON, 2 A OFF, 250 Vac 1x10
4
VDE 0860
RP421 2 A, 50 Vdc, resistive approx. 2x10
6
RP421 1/10hp, 240 Vac, per contact UL 508
RP421 3 A, 380 Vac, AC11 approx. 3x10
4
VDE 0660
RP421 0.18 A, 110 Vdc, DC11 approx. 1x10
5
VDE 0660
RP420
0.6 A, 220 Vac, cosϕ=0.8, single phase motor
approx. 1.3x10
6
Coil data
Nominal voltage 5...110 Vdc
Nominal coil power 500 mW
Operate category 2 / b
Coil versions, DC-coil
Coil Nominal Pull-in Release Maximum Coil Coil
code voltage voltage voltage voltage resistance current
Vdc Vdc Vdc Vdc c mA
005 5 3.5 0.5 9.0 54+10% 92.6
006 6 4.2 0.6 10.8 68+10% 88.2
012 12 8.4 1.2 21.6 270+10% 44.4
024 24 16.8 2.4 43.2 1100+15% 21.8
048 48 33.6 4.8 86.4 4400+15% 10.9
060 60 42.0 6.0 108.0 6540+15% 9.2
110 110 77.0 11.0 198.0 23100+15% 4.8
All figures are given for coil without preenergization, at ambient temperature +20°C
Other coil voltages on request
F0150-B
Insulation
Dielectric strength coil-contacts 4000 V
rms
open contact circuit 1000 V
rms
adjacent contacts 2500 V
rms
Clearance / creepage 8 / 8 mm