The two weaker indications on both sides of the actual marker occur because the locator is
extremelysensitiveto themagneticfieldcomponentsparalleltoitslongaxis.AtpointBandC,
thefieldisperpendiculartothelocatorsonopeakaudioordigitalindicationsareproduced.
When
PlacingStakes,CorrectOrientationisImportant
Forcheckingpurposes,theorientationofthepinrelative
tothelocatorisshowninFigure 11.Checkthepin with
one orientation.Then ro tate the pin 180°.The
orientationthatgives thelargest reading isthe onethat
should be used.This reading
will be positive in the
Northern Hemisphere and negative in the Southern
Hemisphere(Australia,NewZealand,etc.)
An iron pin has two typesof magnetization.One is the
magnetizationinducedbytheEarth’smagneticfield.The
induced magnetization is always downward in the
Northern Magnetic Hemisphere and produces a positive
output
no matter which end of the stake is driven into
the ground.The other type of field is the permanent
magnetization that is fixed to the pin.For maximum
detection,thestakeshouldbedrivenintothegroundso
that the permanent magnetization is in the same
directionasthe
inducedmagnetization.
LocatingManholes,SepticTanksandWellCasings
Themagneticfieldisstrongestattheedgeofashallowmanholecover.Youcaneasilytracethe
edgesofcoversnearthesurface.Thelocatingdepthformanholecoversrangesupto8feet.
The great length of a well
casing provides a strong field at the surface that makes it easy to
locatecasingsburiedupto15feetdeep.