Product Manual
9
SECTION VI: OPERATING RECOMMENDATIONS AND APPLICATION NOTES
Search Procedure
Turn the instrument ON. The gain defaults to Medium
(M). Grasp the locator, as illustrated in Figure 10.
Since the upper sensor is located near the handle of the
instrument (especially if it is being used in the collapsed
position), wristwatches may produce unwanted changes
in the audio signal and in the meter indication.
Therefore, watches should be removed. Keep the
locator away from your shoes as they may contain
magnetic material.
To obtain a maximum coverage area, sweep the locator
from side to side. When the locator comes within range
of an iron object, the signal strength will peak, the
frequency of the audio signal will peak, the bar graph will
expand in the positive or negative direction, and the
digital readout will peak. This is shown in Figure 11.
Figure 10: Searching with the Locator
Figure 11: Illustration of Visual Indicators within
Range of an Iron Object
NOTE: The number of bars shown in the bar graph, the
number displayed in the digital readout, and the frequency
of the audio signal will all depend on the signal strength,
which is affected by the type of iron object detected, its
orientation, and the gain setting.