Manual
Warnings and Faults
975-0298-01-01 4–3
To return to Operating mode:
1. On the System Settings menu, highlight “System Mode,” and
press Enter.
2. Select “Operating” and press Enter.
Using the Standby Button
Pressing and holding the Standby Button produces the same result as
disabling “Invert” and “AC Charge” from the System Settings menu on
the Xantrex XW SCP. Pressing and holding the Standby button does not
affect Charge Controller operation. After disabling inverting and
charging with the Standby button, the system continues to pass AC input
through to the loads.
Pressing and holding the Exit and Standby buttons at the same time puts
the entire Xantrex XW power system (including Charge Controllers) into
standby mode. In standby mode, the Xantrex XW inverter/chargers stop
passing AC input through to the loads, and “Stb” is displayed on Inverter
Information Panel.
After the keypress command to enter standby mode, the Xantrex XW
AGS (if installed) shuts down the generator (if it is running) after a
cool-down cycle.
Warnings and Faults
This section describes how fault and warning messages behave,
and what you should do when they appear. For a complete list of fault
and warning messages specific to the Xantrex XW SCP, along with
recommended actions to correct the fault or warning condition, refer to
Chapter 5, “Troubleshooting”.
Important: The Xantrex XW SCP displays fault and warning messages
for all Xantrex Xanbus-enabled devices in the system. For information
about fault and warnings for other devices, refer to the Troubleshooting
chapter in the Owner’s Guide or Operation Guide for each device.