Installation manual

9
Drive ratings
Single-phase supply voltage: 200…240 V 50/60 Hz
Three-phase motor 200...240 V
Three-phase supply voltage: 200…240 V 50/60 Hz
Three-phase motor 200...240 V
(1)These power ratings and currents are given for an ambient temperature of 50°C (122°F) at the factory-set switching frequency,
used
in continuous operation (factory-set switching frequency of 4 kHz for ATV71H 037M3 to D15M3X and 2.5 kHz for ATV71H D18M3X
to
D45M3X).
Above this factory setting, the drive will reduce the switching frequency automatically in the event of excessive temperature rise.
For continuous operation above the factory setting, derating must be applied to the nominal drive current in accordance with the curves
on page
14.
(2)Current on a line supply with the “Max. prospective line Isc” indicated and for a drive without any external options.
(3)Peak current on power-up for the max. voltage (240 V +10%).
(4)ATV71H 037M3 to D45M3X drives are available with or without a graphic display terminal. Catalog numbers for drives without a graphic
display terminal have the letter Z added at the end, e.g.: ATV71H075M3Z. This option is not available for drives operating in difficult
environmental conditions (5).
(5)Drives with the S337 or 337 extension are designed for use in difficult environmental conditions (class 3C2 in accordance with IEC 721-3-3).
They are supplied with a graphic display terminal.
(6)A line choke must be used (please refer to the catalog).
(7)Drives with the extension 383 are intended for use with synchronous motors.
Inhibit the input phase loss fault (IPL) so that ATV71H 075M3 to U75M3 drives can operate on a single-phase supply
(see Programming Manual). If this fault is set to its factory configuration, the drive will stay locked in fault mode.
Motor Line supply (input) Drive (output) Altivar 71
Power indicated
on plate (1)
Max. line current (2) Max.
prospective
line Isc
Apparent
power
Max. inrush
current (3)
Nominal
current
In
(1)
Max. transient
current (1) for
Catalog number
(4)(5)(7)
at 200 V at 240 V 60 s 2 s
kW HP A A kA kVA A A A A
0.37 0.5 6.9 5.8 5 1.4 9.6 3 4.5 4.9 ATV71H075M3
0.75 1 12 9.9 5 2.4 9.6 4.8 7.2 7.9 ATV71HU15M3
1.5 2 18.2 15.7 5 3.7 9.6 8 12 13.2 ATV71HU22M3
2.2 3 25.9 22.1 5 5.3 9.6 11.0 16.5 18.1 ATV71HU30M3
3 - 25.9 22 5 5.3 9.6 13.7 20.6 22.6 ATV71HU40M3(6)
4 5 34.9 29.9 22 7 9.6 17.5 26.3 28.8 ATV71HU55M3(6)
5.5 7.5 47.3 40.1 22 9.5 23.4 27.5 41.3 45.3 ATV71HU75M3(6)
Motor Line supply (input) Drive (output) Altivar 71
Power indicated
on plate (1)
Max. line current (2) Max.
prospective
line Isc
Apparent
power
Max. inrush
current (3)
Nominal
current
In
(1)
Max. transient
current (1) for
Catalog number
(4)(5)(7)
at 200 V at 240 V 60 s 2 s
kW HP A A kA kVA A A A A
0.37 0.5 3.5 3.1 5 1.3 9.6 3 4.5 4.9 ATV71H037M3
0.75 1 6.1 5.3 5 2.2 9.6 4.8 7.2 7.9 ATV71H075M3
1.5 2 11.3 9.6 5 4 9.6 8 12 13.2 ATV71HU15M3
2.2 3 15 12.8 5 5.3 9.6 11 16.5 18.1 ATV71HU22M3
3 - 19.3 16.4 5 6.8 9.6 13.7 20.6 22.6 ATV71HU30M3
4 5 25.8 22.9 5 9.2 9.6 17.5 26.3 28.8 ATV71HU40M3
5.5 7.5 35 30.8 22 12.4 23.4 27.5 41.3 45.3 ATV71HU55M3
7.5 10 45 39.4 22 15.9 23.4 33 49.5 54.5 ATV71HU75M3
11 15 53.3 45.8 22 18.8 93.6 54 81 89.1 ATV71HD11M3X
15 20 71.7 61.6 22 25.1 93.6 66 99 109 ATV71HD15M3X
18.5 25 77 69 22 27.7 100 75 112 124 ATV71HD18M3X
22 30 88 80 22 32 100 88 132 145 ATV71HD22M3X
30 40 124 110 22 42.4 250 120 180 198 ATV71HD30M3X
37 50 141 127 22 51 250 144 216 238 ATV71HD37M3X
45 60 167 147 22 65 250 176 264 290 ATV71HD45M3X