Power management PowerLogic System Catalogue 2004
PowerLogic System is… PowerLogic System helps you control the cost, quality and reliability of electric power. With PowerLogic System, you can determine where extra capacity exists, identify over-loaded equipment and balance loads on substations, switchboards and other power equipment. By optimising your electrical system, you extend the life of your installation.
General contents Index of catalogue numbers 2 Why use PowerLogic System? 4 Panorama of the PowerLogic range 8 Examples of architectures 12 Current transformers 14 TI Panel instruments XX AMP / VLT IM100 / UM100 FRE CI / CH Kilowatt hour meters CE XX ME Power-monitoring units PM9 PM500 PM700 PM800 XX CM3000 Communication and supervision EGX200 EGX400 MPS100 23 mars 2004 CM4000 XX SMS 432E0100TDM.
32E0200.fm Page 2 Mardi, 25. mai 2004 2:27 14 Index of catalogue numbers Cat. no.
432E0200.fm Page 3 Mardi, 25. mai 2004 2:27 14 Index of catalogue numbers Cat. no.
1
Why use PowerLogic System? Presentation Get all the information you need to manage your electrical installation Today, cost management and improved continuity of service can boost your competitiveness. For this, you need more information concerning the operation of your electrical installation: consumption data, load curves, disturbances, harmonic pollution, available power, etc. PowerLogic System brings you all this information. Information you can count on, where and when you need it.
Why use PowerLogic System? Presentation (cont.) - PowerLogic System, the key to improving your electrical distribution system DB103569 PowerLogic System serves 3 functions: b collection of measurement data b organisation and transmission of measurement data to facilitate analysis by the different departments concerned: production, maintenance, accounting, site management b checking of the results obtained after implementing electrical distribution system improvement solutions.
Why use PowerLogic System? Benefits and applications Presentation DB103446 Reduce energy costs PowerLogic System helps you reduce power consumption and the cost of the energy you use through sub-billing and electrical contract optimisation. E87260 Sub-billing and cost allocation to reduce consumption Metering of energy consumption to: b identify major consumers b allocate costs b make users aware of expenditures.
Why use PowerLogic System? Benefits and applications (cont.) Presentation E87258 Measurement of total harmonic distortion and individual harmonic content b b b b identify sources of harmonic distortion and separate them from sensitive loads determine causes of malfunctions derate power devices (transformers, cables, etc.) implement filtering solutions. Detection and waveform capture of voltage sags and swells Determine the origin of production losses or shutdowns.
Product selection guide Panorama of the PowerLogic range Current transformers Panel instruments TI Name AMP / VLT AMP / VLT current transformer Function ammeter, voltmeter ammeter, voltmeter Technology analog digital Installation DIN rail 4 x 18 mm modules DIN rail 2 x 18 mm modules I/U I/U Measurement accuracy class 1.5 ± 0.
Panorama of the PowerLogic range (cont.
Panorama of the PowerLogic range (cont.
Product selection guide Panorama of the PowerLogic range (cont.
Product selection guide Examples of architectures PowerLogic System can be used in a number of different architectures depending on the layout of the site. It also offers different user profiles simultaneously. Example 1 DB103449 b installation in a small building or isolated equipment room b one or more metering/monitoring units connected to a simple PC (directly or via modem) b for electrical installation monitoring by the maintenance department.
Product selection guide Examples of architectures (cont.) Example 3 DB103451 b installation in a number of buildings linked by a company Intranet b connection of metering/monitoring units to EGX Web servers for integration in the company Ethernet network b all sectors of the company connected to the Intranet have direct access to essential data on the electrical installation via their Web browser.
12
Power-monitoring units Circuit Monitor Series 4000 Functions and characteristics 059162-56 E90463 The PowerLogic Circuit Monitor Series 4000 offers high-performance digital instrumentation, data acquisition and control capabilities. The products integrate easily in power monitoring and control systems due to their Ethernet connections and embedded web server. They are Transparent Ready. These devices are designed for applications where power quality and availability are critical factors.
Power-monitoring units Circuit Monitor Series 4000 Functions and characteristics (cont.) E87291 Selection guide CM4000 CM4000T CM4000XR General Use on LV and HV systems Current and voltage accuracy Energy and power accuracy Nbr of samples/cycle or sample frequency b 0.07 % 0.2 % (1) 512 b 0.07 % 0.
Power-monitoring units Circuit Monitor Series 4000 Functions and characteristics (cont.) The Circuit Monitor has two optional display units, an LCD display and a vacuum fluorescent display (VFD). They may be used for local circuit-monitor setup and operation. 059156 CMDLC display Back-lit LCD display with four lines and 20 characters per line. The display unit has four navigation buttons, a contrast button and a red alarm LED. It connects to the Circuit Monitor via a CAB12 cable, 4.
059141 Power-monitoring units Circuit Monitor Series 4000 Functions and characteristics (cont.) Ethernet ECC21 communication card The ECC21 is an optional Ethernet communication card. It may be installed in the slot in the Circuit Monitor intended for options. It has two main functions: b equip the Circuit Monitor with a fast Ethernet connection over a 10/100 Mbits/s copper link or a 100 Mbits/s fiber-optic link b serve as an Ethernet gateway for devices daisy chained to its RS 485 ModBus port.
Power-monitoring units Circuit Monitor Series 4000 Functions and characteristics (cont.) Input/output blocks may be added to the Circuit Monitor to: b monitor the electrical installation, notably the status of the circuit breakers, and check discrimination between protection devices b measure the consumption of other commodities by counting the pulses sent by water or gas meters b measure the temperature of the transformers b transmit parameters over analog channels to other systems b etc.
059160 Power-monitoring units Circuit Monitor Series 4000 Functions and characteristics (cont.) Input/output modules The input/output modules are installed in the slots of the IOX extender. One module corresponds to either one input or one output. A number of versions are available, digital and analog inputs and outputs, and different voltage levels.
Power-monitoring units Circuit Monitor Series 4000 Functions and characteristics (cont.) Electrical characteristics 059146 Type of measurement Measurement accuracy Current and voltage Power Frequency Power factor Energy: - CM4000/CM4000T - CM4000XR CM4000 + options: ECC21, IOC44 and IOX2411.
Power-monitoring units Circuit Monitor Series 4000 Functions and characteristics (cont.
Power-monitoring units Product selection according to measurement functions Power Meter PM9P/PM9C PM500 PM700 PM700P PM710 PM810 PM820 PM850 General selection criteria Installation On DIN rail Flush mount Flush mount Use on LV distribution systems b b b b b Flush mount b b b Use on LV and HV distribution systems - b b b b b b b Current / voltage accuracy 0.5 % 0.5 % 0.5 % 0.5 % 0.5 % 0.1 % 0.1 % 0.1 % Power / energy accuracy 2% 1% 1% 1% 1% 1% 0.5 % 0.
Product selection according to measurement functions (cont.) Power-monitoring units Circuit Monitor CM3250 CM3350 Micrologic control units for low-voltage circuit breakers CM4000 CM4000XR CM4000T A P H Display in front and module on DIN rail Display in front and module inside switchboard Integrated in the circuit breaker b b b b b b b b b b b b b - - - 0.1 % 0.1 % 0.07 % 0.07 % 0.07 % 1.5 % (1) 1.5 % (1) 1.5 % (1) 0.5 % 0.5 % 0.2 % 0.5 % 0.2 % - 2.0 % (1) 2.
Power-monitoring units Product selection according to measurement functions (cont.
Product selection according to measurement functions (cont.
Power-monitoring units Power Meter PM500 Functions and characteristics 062052-D The Power Logic PM500 Power Meter provides all measurement capabilities required to monitor an electrical installation in a single 96 x 96 mm unit. It offers a number of advantages over analogue meters. Ideal for metering and monitoring applications, it can be integrated in a PowerLogic system to increase the reliability of your installation while cutting costs. Applications Panel instrumentation.
Power-monitoring units Power Meter PM500 Functions and characteristics (cont.) E88968 PM500 For LV and HV distribution systems Current and voltage accuracy Energy and power accuracy (IEC 61036) True rms measurements up to Maximum number of snap-in modules Display Direct voltage connection b 0.
Power-monitoring units Power Meter PM500 Functions and characteristics (cont.
Panel instruments 72 x 72 UM100 digital voltmeters 055793-41 Function The UM100 is a digital voltmeter designed to measure AC voltages. It provides front panel readings on switchboards and is not equipped for communication. A single device covers all alternating voltages from 0 to 690 V.
Panel instruments 72 x 72 IM100 digital ammeters 055791-41 Function The IM100 is a digital ammeter designed to measure AC currents. It provides front panel readings on switchboards and is not equipped for communication. A single device covers current-transformer ratings from 5 to 8000 A.
Functions and characteristics Power-monitoring unit Power Meter Series 600 054530 The PM600, PM620 and PM650 Power Meters have the following functions: true rms measurement of voltage, current, frequency, power and power factor measurement of harmonic distortion of current and voltage metering of active and reactive energy.
Functions and characteristics Power-monitoring unit (cont.) Power Meter Series 600 (cont.) Electrical characteristics E58796 Type of measurement Measurement accuracy Data update rate Input-voltage characteristics 1 2 3 4 5 2-line liquid crystal display. Up/down arrows. Contrast button to adjust the display contrast. Button used to scroll through available modes. Button used to select modes and setup, resets and diagnostics values.
Functions and characteristics Power-monitoring unit Circuit Monitor Series 2000 E60626 The CM2150, CM2250, CM2350 and CM2450 Circuit Monitors have the following functions: customary measurements: instantaneous and min/max values of voltage, current, power, energy, power factor, frequency, etc.
Functions and characteristics Power-monitoring unit (cont.) Circuit Monitor Series 2000 (cont.
Functions and characteristics Power-monitoring unit (cont.) Circuit Monitor Series 2000 (cont.) Input/output modules IOM 054521 Input/output modules can easily be added to the Circuit Monitor.
Schneider Electric 11 mars 2002 432E2240.
Power-monitoring units Circuit Monitor Series 3000 Functions and characteristics E90463 The Power Logic Circuit Monitor CM3250 and CM3350 are high-performance acquisition and control devices offering numerous measurement functions. They integrate easily in power monitoring and control systems due to their Ethernet connections and embedded web server. They are Transparent Ready.
Power-monitoring units Circuit Monitor Series 3000 Functions and characteristics (cont.) E94209 Selection guide CM3250 CM3350 General b 0.1 % 0.5 % 128 b 0.1 % 0.
Power-monitoring units Circuit Monitor Series 3000 Functions and characteristics (cont.) The Circuit Monitor have two optional display units, an LCD display and a vacuum fluorescent display (VFD). They may be used for local circuit-monitor setup and operation. 059156 CMDLC display Back-lit LCD display with four lines and 20 characters per line. The display unit has four navigation buttons, a contrast button and a red alarm LED. It connects to the Circuit Monitor via a CAB12 cable, 4.
059141 Power-monitoring units Circuit Monitor Series 3000 Functions and characteristics (cont.) Ethernet ECC21 communication card The ECC21 is an optional Ethernet communication card. It may be installed in the slot in the circuit monitor intended for options. It has two main functions: b equip the circuit monitor with a fast Ethernet connection over a 10/100 Mbits/s copper link or a 100 Mbits/s fiber-optic link b serve as an Ethernet gateway for devices daisy chained to its RS 485 ModBus port.
Power-monitoring units Circuit Monitor Series 3000 Functions and characteristics (cont.) Electrical characteristics 62109 Type of measurement Measurement accuracy Current and voltage Power Frequency Energy Data update rate Input-voltage Measured voltage characteristics Measurement range Impedance Frequency measurement range Input-current CT ratings characteristics Measurement range Permissible overload Series 3000 + optional ECC21 or IOC44.
Power-monitoring units Circuit Monitor Series 3000 Functions and characteristics (cont.) Safety E87309 Europe U.S. and Canada e, as per IEC 61010 UL508 Communication RS 485 port (1) Example of a CM3250 HTML page showing instantaneous values.
PB100708 Power-monitoring units Power Meter Series 700 Functions and characteristics The PowerLogic Power Meter Series 700 offers all the measurement capabilities required to monitor an electrical installation in a single 96 x 96 mm unit extending only 50 mm behind the mounting surface. With its large display, you can monitor all three phases and neutral at the same time.
Power-monitoring units Power Meter Series 700 Functions and characteristics (cont.) DB101047 Selection guide PM700 PM700P PM710 General b 0.5 % 1.0 % b 0.5 % 1.0 % b 0.5 % 1.
Power-monitoring units Power Meter Series 700 Functions and characteristics (cont.) Electrical characteristics PB100710 Type of measurement Measurement accuracy Current and voltage Power Frequency Active energy Reactive energy Data update rate Input-voltage Measured voltage characteristics Rear view of Power Meter Series 700.
Power-monitoring units Power Meter Series 700 Functions and characteristics (cont.) Safety Europe U.S. and Canada e, as per IEC 61010-1 UL508 Communication RS 485 port (PM710) 2-wire, up to 19200 bauds, Modbus RTU, SELV circuit, 6 kV impulse (double insulation) Display characteristics Dimensions 73 x 69 mm Back-lit green LCD (6 lines total, 4 concurrent values) Firmware characteristics Min./max. Worst min. and max. with phase indication for voltages, currents and THD. Min. and max.
Power-monitoring units Power Meter Series 800 Functions and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement capabilities required to monitor an electrical installation in a single 96 x 96 mm unit. With its large easy-to-read display, you can monitor all three phases and neutral at the same time. The anti-glare and scratch resistant display features an intuitive interface with context-sensitive menus.
Power-monitoring units DB100712 2 1 Power Meter Series 800 Functions and characteristics (cont.) Selection guide 3 PM810 PM820 PM850 General Use on LV and HV systems Current and voltage accuracy Energy and power accuracy Number of samples per cycle b 0.1 % 1% 128 b 0.1 % 0.5 % 128 b 0.1 % 0.
Power-monitoring units Power Meter Series 800 Functions and characteristics (cont.) Electrical characteristics PB100315 Type of measurement Rear view of Power Meter Series 800. True rms up to the 63rd harmonic On three-phase AC system (3P, 3P + N) 128 samples per cycle Measurement Current and voltage ±0.075 % of reading + ±0.025 % of full scale accuracy Power PM810 ±0.5 % of reading + ±0.025 % of full scale PM820/PM850 ±0.15 % of reading + ±0.025 % of full scale Frequency ±0.01 Hz from 45 to 67 Hz ±0.
Power-monitoring units Power Meter Series 800 Functions and characteristics (cont.
Power-monitoring units Power Meter Series PM9 Functions and characteristics PB100646-43 The PowerLogic Power Meter Series PM9 offers all the measurement capabilities required to monitor an electrical installation in a 4-module case (18 mm modules). They can be used to monitor 2-, 3- and 4-wire low-voltage systems and connect to external current transformers. With the large backlit display, you can monitor all three phases at the same time.
Power-monitoring units Power Meter Series PM9 Functions and characteristics (cont.) Selection guide PM9P PM9C 1P + N, 3P, 3P + N b 0.5 % 2% 450 V b 0.5 % 2% 450 V 3 phases and neutral Phase-to-neutral and phase-to-phase b b b b Total and per phase Total Total b b b b b b b b 2 quadrants 2 quadrants b b b b Present and max.
Power-monitoring units Power Meter Series PM9 Functions and characteristics (cont.) Electrical characteristics Type of measurement On single-phase (1P + N) or threephase (3P, 3P + N) AC systems Measurement accuracy Current and voltage 0.5 % of reading Power 2 % of reading from pf 0.8 leading to 0.5 lagging Frequency 0.2 Hz Power factor 2 % from 0.5 leading to 0.
Communication and supervision General information on powermonitoring software Software, a tool serving site operation. A site can be compared to a living organism. The power system manger has no control over the changes that affect this organism, but must ensure that it continues to receive the energy it requires. Similar to a doctor, the power system manager must carry out preventive measures and diagnose and remedy any problems that occur.
Communication and supervision General information on powermonitoring software (cont.) Automatic tasks Software can execute tasks automatically, triggered by: b a date b an event b an alarm. These tasks may concern devices (reset, start of a particular function) or system users (transmission of an e-mail, etc.). Manual commands Power-monitoring software can also be used to control devices (e.g. open or close a circuit breaker).
Communication and supervision SMS software SMS is a complete power-monitoring software family. Depending on the required applications and functions, the SMS family offers different software products: b PMX1500 b SMS121 b SMS1500. SMS software can communicate with all communicating devices installed in the electrical-distribution system: b Power Meters and Circuit Monitors b low-voltage circuit breakers b Sepam protection relays b all devices implementing the Modbus protocol.
Communication and supervision SMS software (cont.) E87268 Waveform display and harmonic analysis The data is presented in graphs. The current and voltage waveforms may be viewed simultaneously or individually, and can be printed. If the waveform capture is over four cycles, it is possible to display the percentage of each harmonic order and the total harmonic distortion (THD). E87269 Event logging SMS logs all events including alarms.
Communication and supervision SMS software (cont.) E87272 Automatic tasks The available tasks include launching programs, resetting devices, sending e-mail, data acquisition and waveform capture. A task may be launched when an alarm is detected or at a precise time set by the user. Animated graphics via the GFX option The GFX interactive graphics option offers a wide range of presentations, including single-line diagrams, electrical switchboards and site and building diagrams.
SMS software (cont.
Power-monitoring units Circuit Monitor Series 4000 Installation and connection DB101816 3-wire connection with 2 CTs and no PT DB101817 4-wire connection with 4 CTs and 3PTs 432E3100.
Power-monitoring units Circuit Monitor Series 4000 Installation and connection (cont.) IOX input/output extender E90178 DB102015 Ethernet ECC21 communication card E90180 IOC44 input/output card 1 avril 2004 432E3100.
Circuit Monitor Series 4000 Installation and connection (cont.) Power-monitoring units E94390 E94391 E94389 CM4000 / CM4000XR dimensions E94394 E94392 E94393 CM4000T dimensions 432E3100.
Circuit Monitor Series 4000 Installation and connection (cont.) Power-monitoring units E87280 Mounting on a backplate E88974 E88976 E88975 Mounting possibilities Vertical mounting. Horizontal mounting. E87285 E87286 CMDLC/CMDVF dimensions E94377 Mounting on a backplate 1 avril 2004 432E3100.
Power Meter PM500 Installation and connection Power-monitoring units E90181 4-wire connection with 3 CTs and no PT Connection example. DB100644 3-wire connection with 2 CTs and 2 PTs Connection example. Note: Other types of connection are possible. See product documentation. 432E3110.
Power-monitoring units Power Meter PM500 Installation and connection (cont.) IO22 Alarm module DB100574 DB100645 Modbus RS 485 module (1) Flip switches 1 and 2 in the direction of the arrow to insert a resistance of 120 Ω. This resistance should be inserted when the PM500 is located at the end of an RS 485 line. (1) Volt free (external power supply). IO02 2 Puls module DB100557 DB100573 IO11 Puls module (1) Volt free (external power supply). DB100575 AO20 4-20 mA module 30 mars 2004 432E3110.
Power Meter PM500 Installation and connection (cont.) Power-monitoring units E88973 E88972 E88971 Dimensions DB101099 Front-panel mounting 432E3110.
Installation and connection Power-monitoring unit Power Meter Series 600 E92127 4-wire connection with 3 CTs and no PT 432E3120.
Installation and connection Power-monitoring unit (cont.) Power Meter Series 600 (cont.) E58799 E58791 PM600 dimensions E62200 E58792 PM600 display dimensions E62229 Mounting on a panel Schneider Electric 21 mars 2002 432E3120.
Installation and connection Power-monitoring unit (cont.) Circuit Monitor Series 2000 E92128 4-wire connection with 4 CTs and 3 PTs 432E3130.
Installation and connection Power-monitoring unit (cont.) Circuit Monitor Series 2000 (cont.) E92130 E62230 E92129 CM2000 E62232 E62231 E62299 CMA100 adapter Schneider Electric E62235 E62234 E62233 SMA220 surface-mount enclosure 11 mars 2002 432E3130.
Power-monitoring units Circuit Monitor Series 3000 Installation and connection E94519 3-wire connection with 2 CTs and no PT E94520 4-wire connection with 4 CTs and 3PTs 432E3140.
Power-monitoring units Circuit Monitor Series 3000 Installation and connection (cont.) E90178 Ethernet ECC21 communication card E90180 IOC44 input/output card 23 mars 2004 432E3140.
Circuit Monitor Series 3000 Installation and connection (cont.) Power-monitoring units E94211 E94210 E94212 Dimensions E94220 E94221 Mounting on DIN rail Vertical mounting. 432E3140.FM/4 E94217 E94219 E94216 E94218 E94215 Mounting possibilities Horizontal mounting. 23 mars 2004 Vertical mounting.
Circuit Monitor Series 3000 Installation and connection (cont.) Power-monitoring units E87285 E87286 CMDLC/CMDVF dimensions E94377 Mounting on a backplate 23 mars 2004 432E3140.
UM100 voltmeter IM100 ammeter Installation and connection Panel instrumentation E95299 UM100 connection E95297 IM100 connection 432E3150.
UM100 voltmeter IM100 ammeter Installation and connection (cont.) Panel instrumentation E95301 E95300 UM100/IM100 dimensions E95302 Front-panel mounting 2 avril 2004 432E3150.
Power Meter Series 700 Installation and connection Power-monitoring units DB101040 DB101041 DB101039 Dimensions DB101042 Front-panel mounting 432E3160.
Power Meter Series 700 Installation and connection (cont.) Power-monitoring units DB102013 4-wire connection with 3 CTs and no PT Connection example. DB102014 3-wire connection with 2 CTs and 2 PTs Connection example. Note: Other types of connection are possible. See product documentation. 24 March 2004 432E3160.
Power Meter Series 800 Installation and connection Power-monitoring units DB100563 DB100564 DB100562 Dimensions DB100565 Front-panel mounting 432E3170.
Power Meter Series 800 Installation and connection (cont.) Power-monitoring units DB100576 4-wire connection with 3 CTs and no PT Connection example. DB100577 3-wire connection with 2 CTs and 2 PTs Connection example. Note: Other types of connection are possible. See product documentation. 24 mars 2004 432E3170.
Power Meter Series 800 Installation and connection (cont.) Power-monitoring units DB101837 PM8M22 module DB101834 PM8M2222 module 432E3170.
Power Meter Series 800 Installation and connection (cont.) Power-monitoring units DB101835 PM8M26 module internal 24 V DC power supply DB101836 PM8M26 module external power supply 24 mars 2004 432E3170.
Power Meter Series PM9 Installation and connection Power-monitoring units DB101950 PM9P and PM9C dimensions 432E3180.
Power Meter Series PM9 Installation and connection (cont.) Power-monitoring units DB101932 PM9P/4-wire connection with 3 CTs Connection example. DB101934 PM9C/4-wire connection with 3 CTs Connection example. Note: other types of connection are possible. See product documentation. 24 mars 2004 432E3180.
Dimensions Current transformers 0 Cat. no. 16540 to 16544 Cat. no. 16537 and 16538 E58381 Cat. no. 16526 to 16535, 16476 to 16483 E58378 E58375 Cat. no. 16523 and 16524, 16473 and 16474 Cat. no. 16518 to 16521, 16468 to 16471 E58382 Cat. no. 16509 to 16515, 16459 to 16465 E58379 E58376 Cat. no. 16500 to 16506, 16451 to 16456 E58383 E58380 E58377 TI current transformers Cat. no. 16545 to 16547 Cat. no. 16548 and 16549 E90391 E90390 Cylinders Cat. no. 16550 432E3190.fm/2 Cat. no.
Dimensions Panel instruments 0 DB103473 Analog ammeters and voltmeters DB103474 Digital ammeters, voltmeter and frequency meter DB103475 DIN rail CMA and CMV selector switches DB103476 72 x 72 analog ammeters and voltmeter Protection cover Terminal M4 96 x 96 analog ammeters and voltmeter DB103481 Protection cover Terminal M4 8 avril 2004 432E3190.
Dimensions (cont.) Panel instruments 0 48 x 48 CMA and CMV selector switches DB103477 3.2 (or 4.8) 24.1 (or 33) 22.3 (or 30.5) (with adapter) DB103478 UM100 voltmeter, IM100 ammeter DB103479 CI impulse counter and CH hour counter DB103480 48 x 48 CH hour counters 432E3190.
Dimensions Kilowatt hour meters 0 DB103482 CE and CEr kilowatt hour meters DB103483 ME1, ME1z and ME1zr watt hour meters DB103484 ME3, ME3zr, ME4, ME4zr, ME4zrt watt hour meters 8 avril 2004 432E3190.
Communication interfaces and associated services Communication and supervision Switchboard-data acquisition and monitoring make it possible to anticipate events. In this way, they reduce customer costs in terms of operation, maintenance and investment. Serial link With communication technology, it is no longer necessary to be physically present on the site to access information. Data is transmitted by networks.
Communication interfaces and associated services (cont.) Communication and supervision E90463 Ethernet link Using modern Web technologies, the operator can access information from any PC connected to the network, with all the required security. DB101069 The Ethernet EGX200 gateway or the EGX400 and MPS100 servers provide adaptation between Modbus-RS 485 and Modbus-Ethernet TCP/IP (1). Ethernet communication architecture.
Ethernet EGX200 gateway Communication and supervision Function PB100707_68 E90463 The EGX200 gateway serves as an Ethernet coupler for the PowerLogic System devices and for any other communicating devices operating under the Modbus RS 485 protocol. The EGX200 gateway offers complete access to all status and measurement information provided by the connected devices, for example, via the SMS software installed on a PC.
Ethernet EGX400 server Communication and supervision Function PB100704_68 E90463 The EGX400 server is used as an Ethernet coupler for the PowerLogic System devices and for any other communicating devices operating under the Modbus RS 485 protocol. It contains HTML pages (set up using WPG) that can be accessed using a standard internet browser. The HTML pages are used to display the information provided by the devices connected to the server.
Communication and supervision Ethernet EGX200 gateway Ethernet EGX400 server DB100978 Characteristics EGX200 and EGX400 Weight Dimensions (H x W x D) Mounting Power supply Operating temperature Humidity rating 700 g 25 x 190 x 115 mm Symmetrical or asymmetrical DIN rail Front or side position 24 V DC 100-240 V AC/24 V DC adapter supplied -30 °C to +80°C 5 % to 95 % relative humidity (without condensation) at +40 °C Compliance with standards 1 2 3 Power connector. Ethernet indication LEDs.
Ethernet EGX200 gateway Ethernet EGX400 server (cont.) Communication and supervision DB100970 DB100969 Installation Side mounting on DIN rail DB100972 DB100971 Front mounting on DIN rail 24 March 2004 432E4020.
Communication and supervision WPG software tool HTML-page generator Function DB101034 Very easy to use, the WPG software tool generates HTML pages for the EGX400 server. It is used to: b select the devices connected to the server b transfer the HTML pages corresponding to the selected devices to the server.
Catalogue numbers Power-monitoring units Digital Voltmeter UM100 (Merlin Gerin brand) Supply voltage 48-115 V AC/DC 220-240 V AC 380-415 V AC 50831 50832 50834 Supply voltage 48-115 V AC/DC 220-240 V AC 380-415 V AC 50835 50836 50837 E38717 000 I . Max E38717 Digital Ammeter IM100 (Merlin Gerin brand) 000 I . Max E89554 Power Meter Series 500 (Merlin Gerin brand) LV and MV application - 0.
Catalogue numbers Power-monitoring units (cont.) Circuit Monitor Series 3000 (Merlin Gerin/Square D brand) Merlin Gerin brand E95190 CM3250 CM3350 E67943 CMDLC CMDVF Advanced inst.,On-board data logging, waveform capture, cl 0.
Catalogue numbers Power-monitoring units (cont.) CM4000 I/O options (cont.
Catalogue numbers Supervision Software Software E62305 SMS121 PMX1500 SMS1500 SMS3000 SMS1000 GFX1000 System Manager Software: single device communication software SMS121ENG SMS121FRA SMS121ESP Power Monitoring Explorer: multiple device supervisory PMX1500ENG software, stand alone PMX1500FRA PMX1500ESP Power Monitoring Explorer: multiple device supervisory SMS1500ENG software, advanced features, stand alone SMS1500FRA SMS1500ESP System Manager Software: client/server supervisory SMS3000ENG softwar
Catalogue numbers Ethernet gateways and Power servers Ethernet gateways and Power servers (Merlin Gerin/Square D brand) EGX200 Ethernet Gateway, double port EGX200MG (Merlin Gerin brand) EGX200 ECC21 Please refer to CM3000/4000 accessories list EGX400 Ethernet Gateway, double port + Web server EGX400MG (Merlin Gerin brand) EGX400 MPS100 Micro Power Server with automatic notification 33507 PWRSRV750 Power Server with embedded user interfaces PWRSRV750MG (Merlin Gerin brand) PWRSRV750 SD700 L
Catalogue numbers Communication Interfaces and Accessories Modbus pre-wired system 6 SubD 9 pin connector junction block 50963 CSD309 9 pin SubD connector with screw terminals 50964 CCP303 Masterpact or Compact pre-wired cable (4 RS485 wires + 2 power wires) 3m 50961 CCS303 Pre-wired cable (4 RS485 wires) 3m 50962 CCR301 RS485 roll cable (2 RS485 wires + 2 power wires) 60 m roll 50965 MCA485 Multi-point Communications Adapter, RS485 MCT485 Multi-point Communications Terminator, RS485,
Catalogue numbers LV installation Control and Monitoring (Digipact Merlin Gerin) Interfaces and auxiliaries Data concentrator DC150 E38720 Supply voltage N IN GERI MERL 110-240 V AC/115-125 V DC 50823 JBus BBus com com error 24V OK error 1 3 N°1 N°1 Indication and control interface SC150 50784 Powered by the DC150 module 50785 E38727 Powered by the DC150 module E38719 Indication and local control module CLS150 IN LIN GER MER CLS150 co C C O L on L/R reset off Communicating auxilia
89, boulevard Franklin Roosevelt F - 92500 Rueil-Malmaison (France) Tel : +33 (0)1 41 29 85 00 http://www.schneider-electric.com As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper. http://www.schneider-electric.