Installation guide
Introducing the Modbus Plus Network
890 USE 100 00
23
1.8 Designing for Process Speed
Figure 12 is an example of a hierarchical approach using Bridge Plus
devices. The application uses a relatively large count of nodes, but no
network contains more than six nodes.
Token access and message handling can be rapid within the networks
that are used for the control of timecritical processes. For example,
the node count on a given network can be reduced to the minimum that
is required for that portion of the application. Node counts on other
less-critical networks can be increased.
Message transactions across the bridges are slower than in single
networks, because the rotation times of the multiple networks are a
factor in receiving data responses from destinations. Because of this,
internetwork traffic should be dedicated to transactions that are less
critical for timing, such as for data collection and program
downloading.
BP = BRIDGE PLUS
BPBP
P230P230
BPBP
UI = USER INTERFACE
HOST
UI UI
UI UIUI UI
CPU
BPBP
CPU CPU CPU CPU CPU
CPU CPU CPU CPU CPU CPU
Figure 12 Hierarchical Configuration for Improved Throughput