User manual
Magelis D - 15
2. Creation in XBT L100•
D
- In "Action", select "Access to application page".
- In the pages, select page 3.
- Confirm by clicking on OK.
This page includes functional command links (see chapter B, section
Commands sent via functional links, Page 29).
To create a functional command link for startup:
- Select the Insert Link command from the Edit menu (link on the right
by default).
- In "Action", select "Toggle command".
- Click on the Modify... button.
- Modify the equipment in API_PLC.
- Modify the word number by entering 10 in the "i" field and 10 in the "j"
field.
- Confirm the variable by clicking on OK.
- Confirm the "Insert Link L2" page by clicking on OK.
To create a functional command link for step-by-step mode:
- Select the Insert Link command from the Edit menu (link on the right
by default).
- In "Action", select "Impulse command".
- Click on the Modify... button.
- Modify the equipment in API_PLC.
- Modify the word number by entering 15 in the "i" field and 15 in the "j"
field.
- Confirm the variable by clicking on OK
- Confirm the "Insert Link L3" page by clicking on OK.
Conveyor
-----
Startup
On/Off
Step-by-step
On
-----
Back