User manual

C - 80 Magelis
7. Description of dialog-table words
If the dialog table has not imposed a backlight color (because this
function has never been called since the application started) or if the
dialog table has asked for the backlight color not to be forced (by writing
the value 0x0100 to the "Advanced functions" word) then the backlight
color is that imposed by the page displayed.
Function 2
:
The password is defined as follows:
If the dialog table has not imposed a password (because this function
has never been called since the application started) or if the dialog table
is not imposing a password (by writing the value 0x0200 to the
“Advanced functions” word) then the password level is that defined by
the display unit user.
Conversely, if the dialog table has asked at least once for the password
to be either A+B (via the value 0x0203) then whatever the password
requested by the user, the password level will be A+B, that imposed by
the dialog table (same logic as for other passwords).
00000C BA
7 0
Password Function parameters (LSB)
Unchanged/Reinitialization 0
A selected 1
B selected 2
B+A selected 3
C selected 4
C+A selected 5
C+B selected 6
C+B+A selected 7
XBT ref. Note
N200/N400/N410
NU400
R400/R410
No choice of backlight color