7. Description of dialog-table words
Log fill level
This word uses 2 bytes. The most-significant byte is reserved and is
written to the value 0 by the terminal on each cycle of the dialog table.
The least-significant byte contains a number between 0 and 100, which
indicates how much of the log is in use as a percentage.
NOTE: The log fill level is zero if the log is empty. The fill level is 100 if and
only if the log is completely full.
Application checksum
This word contains a checksum denoting the version of a dialog
application. It is only found in the dialog table. The PLC can thus monitor
that the dialog application is the correct one.
Bit no. Bit name
5 PRINTING_IN_PROGRESS
6 PRINTING_FAULT
7 PRINTING_STOPPED
8 reserved (0)
9 reserved (0)
10 reserved (0)
11 LOW_CURRENT_LANGUAGE_NUMBER
12 HIGH_CURRENT_LANGUAGE_NUMBER
13 NEW_TIME_PROVIDED_BY_OPERATOR
14 reserved (0)
15 reserved (0)
XBT -> PLC Reserved (0) Log fill level
XBT -> PLC Application identification
XBT ref. Note
N200/N400/N410
NU400
No checksum