User manual

Connecting XBT Terminals
33003962 11/2011 61
Distinguishing XBT Terminals by Power Supply
Overview
For exchanging software configuration data with Vijeo-Designer Lite, connect your
XBT terminal to a PC running the Vijeo-Designer Lite configuration software.
The correct cabling depends on whether your XBT terminal is
z powered by the PLC
z powered by an external 24 VDC power supply
The following XBT terminals need 5 V power that must be supplied by the PC in this
case:
z XBT N200
z XBT N400
z XBT R400
z XBT RT500
NOTE: XBT RT500 terminals are protected against accidental connection to higher
voltages (up to 30 V) but the other terminal types are not and will be damaged.
The following XBT terminals need an external power supply supplying 24 VDC:
z XBT N410
z XBT N401
z XBT NU400
z XBT R410
z XBT R411
z XBT RT511
CAUTION
OVERVOLTAGE DAMAGE TO EQUIPMENT
Make sure to connect the following terminals only to a source providing 5 VDC.
z XBT N200
z XBT N400
z XBT R400
z XBT RT500
Failure to follow these instructions can result in injury or equipment damage.