User manual

Chapter 3 Specifications
3-27
Serial Interfaces
Serial Interface (COM1)
This interface is used to connect an RS-232C serial cable. A 9-pin SUB-D plug connector is used.
OT unit side
Cable side
RS-232C
*1 The RI/VCC selection for Pin #9 is switched via software. The VCC output is not protected against
overcurrent. To prevent damage or a unit malfunction, use only the rated current.
OT Connector XM2C-0942-502L (OMRON Co.)
Interfit Bracket #4-40 inch screws are used.
Recommended Cable Connector XM2D-0901 (OMRON Co.)
Recommended Cable Cover XM2S-0913 (OMRON Co.)
Recommended Jack Screw XM2Z-0073 (OMRON Co.)
Pin
Arrangement
Pin No.
RS232C
Signal Name Direction Meaning
1 CD Input Carrier Detect
2 RD(RXD) Input Receive Data
3 SD(TXD) Output Send Data
4 ER(DTR) Output Data Terminal Ready
5 SG - Signal Ground
6 DR(DSR) Input Data Set Ready
7 RS(RTS) Output Request to Send
8 CS(CTS) Input Send Possible
9 CI(RI)/VCC Input
Called status display
+5V
±5% Output 0.25A
*1
Shell FG -
Frame Ground
(Common with SG)
9
6
5
1
(OT unit side)