5/79
Instantaneous auxiliary contact blocks for connection by screw clamp terminals
For use in normal operating environments
In order to mount an LAD 8N on an LC1 D80 to D95, a set of shims must be ordered separately, see page 5/85.
Clip-on mounting
(1)
Number of
contacts per block
Composition Reference Weight
kg
Front 1 1 LAD N10 0.020
1 LAD N01 0.020
2 1 1 LAD N11 0.030
2 LAD N20 0.030
2 LAD N02 0.030
4 2 2 LAD N22 0.050
1 3 LAD N13 0.050
4 LAD N40 0.050
4 LAD N04 0.050
3 1 LAD
N31 0.050
4 i
ncl. 1 N/O & 1 N/C make before break 2 2 LAD C22 0.050
Side 2
1 1 LAD 8N11 0.030
2 LAD 8N20 0.030
2 LAD 8N02 0.030
For terminal referencing conforming to EN 50012
Front on 3P contactors and
4P contactors 20 to 80 A
2 1 1 LAD N11G 0.030
4 2 2 LAD N22G 0.050
Front on 4P contactors
125 to
200 A
2
1 1 LAD N11P 0.030
4 2 2 LAD N22P 0.050
With dust and damp protected contacts, for use in particularly harsh industrial environments
Front 2 2 LA1 DX20 0.040
1 1 LA1 DX11 0.040
2
LA1 DX02 0.040
2 2 LA1
DY20 (2) 0.040
4 2 2 LA1 DZ40 0.050
2
1 1 LA1
DZ31 0.060
Instantaneous auxiliary contact blocks for connection by lugs
This type of connection is not possible for blocks with 1 contact or blocks with dust and damp protected contacts.
For all other instantaneous auxiliary contact blocks, add the gure 6 to the end of the references selected above.
Example: LAD N11 becomes LAD N116.
Instantaneous auxiliary contact blocks for connection by spring terminals
This type of connection is not possible for LAD 8, LAD N with 1 contact or blocks with dust and damp protected
contacts. For all other contact blocks, add the gure 3 to the end of the references selected above.
Example: LAD N11 becomes LAD N113.
Instantaneous auxiliary contact blocks for connection by Faston connectors
This type of connection is not possible for LAD 8, LAD N with 1 contact or blocks with dust and damp protected
contacts. For all other contact blocks, add the gure 9 to the end of the references selected above.
Example: LAD N11 becomes LAD N119.
(1) Maximum number of auxiliary contacts that can be tted:
Contactors Instantaneous auxiliary contacts Time delay
Front
mounted
Type Number of poles and size Side mounted Front mounted
1 contact 2 contacts 4 contacts
a 3P LC1 D09…D38 1 on LH side and 1 or 1 or 1
LC1 D40A…D65A 1
on LH or 1 on RH side and 1 or 1 or 1
LC1 D80
and D95 (50/60 Hz) 1 on each side or 2 and 1 or 1 or
1
LC1 D80 and D95 (50 or 60 Hz) 1 on each side and 2 and 1 or 1 or
1
LC1 D115 and D150 1 on LH side and 1 or 1 or 1
4P LC1 DT20…DT40 1
on LH side and 1 or 1 or 1
LC1 DT60A
and DT80A 1 on LH or 1 on RH side and 1 or 1 or 1
LC1 D40008,
D65008 and D80 1 on each side or 1 or 1 or 1 or
1
LC1 D115 1 on each side and 1 or 1 or 1 or
1
c 3P LC1 D09…D38 1 or 1 or 1
LC1 D40A…D65A
1 or 1 or 1
LC1 D80
and D95 1 or 1 or 1 or
1
LC1 D115 and D150 1 on LH side and 1 or 1 or 1
4P LC1 DT20…DT40
1 or 1 or 1
LC1 DT60A
and DT80A 1 or 1 or 1
LC1 D40008,
D65008 and D80 2 and 1 or 1 or
1
LC1 D115 1 on each side and 1 or 1 or
1
BC (3) 3P LC1 D09…D38 1
4P LC1 DT20…DT40 1
(2) Device tted with 4
earth screen continuity terminals.
(3) LC: low consumption.
References
TeSys contactors
TeSys D contactors and reversing contactors
Instantaneous auxiliary contact blocks