Specifications
1
2
3
4
5
6
7
8
9
10
82
Ethernet network
Cabling system
ConneXium
™
unmanaged switches
Introduction
Switches are used to increase the limits of
architectures – based on hubs or transceivers –
by separating collision domains.
Higher layer communication is provided between the
ports, and collisions at link layer are not propagated
(ltering). Switches improve performance by better
allocation of the pass band due to the reduction of
collisions and the network load.
Certain Connexium
™
switch models also enable
redundant architectures to be created on twisted pair
copper ring or ber optic.
Switches are “plug & play” devices that do not need any
conguration. They can also be managed remotely via
the SNMP or HTTP protocols for monitoring and
diagnostics purposes.
Specications and references: twisted pair
Switches Copper twisted pair, unmanaged
Interfaces Copper
cable ports
Number and type 5 x 10BASE-T/ 100BASE-TX ports 8 10BASE-T/100BASE-TX ports
Shielded connectors M12 (type D) RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair
100 m
Ethernet services Storage and re-routing of received data, auto
MDI/MDX, automatic negotiation of
10/100 Mbit/s and duplex mode, automatic
change of polarity
–
Topology Number of switches Cascaded Unlimited
Redundant in a ring –
Redundancy – P1 and P2 redundant power supplies
Power supply Voltage 24 V c (18…32) safety extra low voltage (SELV)
Power consumption mA max. 100 125 (290 max.)
Removable connector 5-way M12 (type A, male) 5-way
Operating temperature 0…+ 60 °C
Relative humidity – 10…95% non condensing
Degree of protection IP 67 IP 20
Dimensions W x H x D
60 x 126 x 31 mm
47 x 135 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.210 kg 0.230 kg
Conformity to standards cUL 508 and CSA 22.2 No. 142 cUL 60950, UL 508 and CSA 22.2 No. 142, UL
1604 and CSA 22.2 No. 213 Class 1 Division 2,
e, GL, C-Tick
LED indicators Power supply, link status, line activity P1 and P2 power supplies, Ethernet link/port
status
Alarm relay – Detected power supply fault, detected
Ethernet network fault, or detected
communication port fault (1 A max. volt-free
contact at 24 V c)
Reference TCS ESU 051F0 499 NES 181 00
IP 67 cordsets
Ethernet cordsets Preformed at each end, see page 79
Power supply cables Preformed at each end with M12 female
straight connectors
Preformed at each end with female M12
angled connectors
Length 2 m Length 5 m Length 2 m Length 5 m
Reference XZC P1164L2 XZC P1164L5 XZC P1264L2 XZC P1264L5
Spare power connectors Female M12 straight connector Female M12 angled connector
Reference XZC C12 FDM 50B XZC C12 FCM 50B
Product data sheet
DTE
DTEDTE
DTE DTE
DTE DTE
DTE DTE
DTE
DTEDTE
DTE DTE
DTE
DTEDTE
DTE DTE
DTE DTE
100 Mbps optical
ring
Collision domain
1
Collision domain
2
Collision