Installation guide
Commissioning
96
890USE17100 September 2003
Port Parameters The CFG port supports the following communication parameters:
Connections An STB XCA 4002 programming cable must be used to connect the computer
running the Advantys configuration software or a HMI panel capable of running your
fieldbus protocol to the NIM via the CFG port.
The following table describes the specifications for the programming cable:
LED Indicators LEDs on your NIM give you a visual indication of the operational status of the island
bus on your particular network. The LED array is located at the top of the NIM’s front
panel:
Parameter Valid Values Factory Default Settings
bit rate (baud) 2400/4800/ 9600/9200/ 38400/ 57600 9600 (see 1)
data bits 7/8 8 (see 2)
stop bits 1/2 1 (see 2)
parity none/odd/even even (see 2)
protocol Modbus RTU or Modbus ASCII Modbus RTU
1 To modify the default baud or communication mode parameter, you must use the
Advantys configuration software.
Parameter Description
model STB XCA 4002
function connection to device running configuration software
connection to HMI panel
communications protocol Modbus (either RTU or ASCII mode)
cable length 2 m (6.23 ft)
cable connectors eight-receptacle HE-13 (female)
nine-receptacle SUB-D (female)
cable type multiconductor