Technical information
3/30
Presentation
Modicon M580 automation
platform
Probus DP V1 and Probus PA buses
Probus Remote Master module
Probus DP eldbus
Probus DP is one of the most widely used eldbuses in industry. Based on a
master/slave protocol, only master stations, sometimes called active stations, have
the right to access the bus, with slave, or passive, stations being limited to
responding to interrogations.
Version V0 of Probus only allows cyclic exchanges with I/O, whereas version V1
offers an acyclic message handling channel that can be used for device adjustment
or diagnostics during operation.
The physical link is a single shielded twisted pair, but numerous interfaces are
available for creating all sorts of topologies - tree, star, or ring - including those using
optical ber or a non-physical link.
Gateways can be used to communicate transparently with Probus PA, one of the
most commonly used standards in process applications for connecting
instrumentation. Probus PA can be used to supply devices across the network and
also to install sensors in potentially explosive zones (ATEX).
Unity Pro
PRM master
PRM Com DTM
Ethernet
Probus PA
PRM
Probus DP
DP Class 1
Probus Remote Master (PRM) module
Presentation
The Probus Remote Master (PRM) module is connected to the Ethernet Modbus
TCP/IP network via its integrated 2-port switch, as close as possible to the process
and the instrumentation.
The PRM module can be used to connect Modicon Quantum, Premium, M580, and
M340 PLCs to Probus DP V1 via the I/O scanner function.
Irrespective of the type of PLC, only one product reference is required and setup is
identical, thus reducing training and maintenance costs.
Two versions are available, standard and tropicalized, so as to adapt to any type of
environment.
The PRM module is open to Asset Management tools. A dedicated communication
DTM is supplied with the product, thus allowing any compatible FDT standard tool to
remotely adjust devices on Probus using Ethernet.
Conguration
From a single Unity tool, the user can create the Probus conguration, the PLC
application, and congure or calibrate devices.
The latter are integrated in the Unity catalog via their DTMs if they exist, or their gsd
les.
The I/O scanner conguration is created implicitly in Unity Pro using the Probus
conguration. The parameters assigned by default help optimize performance, as well
as the consistency of I/O data in the PLC application, irrespective of the PLC
platform.
Similarly, the I/O variables dened and presymbolized in the DTMs can be used
directly in the application. Finally, the screens integrated in Unity Pro, together with
the diagnostic functions integrated in the device DTMs simplify application
maintenance.
Processors:
page 1/18
I/O architectures:
page 2/2
Software:
page 4/2
Ruggedized Modicon M580 modules:
page 5/2
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10