Modicon M580 automation platform Catalog January 2014
How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete set of industrial automation catalogs all on a handy USB key for PC or in an application for tablets Digi-Cat, a handy USB key for PC > Convenient to carry > Always up-to-date > Environmentally friendly > Easy-to-share format Contact your local representative to get your own Digi-Cat e-Library, the app for tablets If you have an iPad®: > Go to the App Store and search for e-Library > or scan the QR co
General contents Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 I/O architectures . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Ruggedized Modicon M580 modules . . . . . . 5 Standards and certifications . . . . . . . . . . . . . . 6 Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 2 3 4 5 6 7 8 9 10 1/0
Contents 1 - Presentation, processor modules, single-rack and multirack configurations Presentation b General presentation............................................................................. page 1/2 b Composition ......................................................................................... page 1/8 1 b Compatibility........................................................................................ page 1/14 Processor modules Selection guide . . . . . . . . . . . . . . . . . .
General presentation Modicon M580 automation platform Innovative 1 2 Modicon M580 ePAC Control at the heart of PlantStruXure The Modicon M580 ePAC (Programmable Automation Controllers) feature openness, flexibility, robustness and sustainability. The M580 are designed with an Ethernet backbone to optimize connectivity and communications. They support X80 common I/O modules which can be easily integrated into its architecture.
General presentation (continued) Modicon M580 automation platform Innovative Innovative (continued) ® et Ti 1 Advanced technologies > Based on high-speed dual-core processor (ARM type) > High-speed communication, application and execution > Innovative mechanical and electronic design for high EMC immunity and -m e-to ark m ruggedness that is superior to the required IEC standards 2 > Supports extended temperature range from −25°C to +70°C Modicon M580 design is compliant with automation standards
General presentation (continued) Simple and flexible Simple and flexible Ti -m e-to ark m et 1 Modicon M580 automation platform Flexibility in design > Flexible topology allows simple integration of devices > Ability to mix remote equipment, distributed equipment and other devices on the same Ethernet field network with complete software integration > Transparent access to data through Ethernet backbone > Simple HMI integration via third port on remote I/O head > Interface to other popular fieldbus
General presentation (continued) Modicon M580 automation platform Simple and flexible nce Exce na nce lle Main te Simple and flexible (continued) 1 Easy diagnostics > Ethernet delivers information everywhere > Simple remote and mobile diagnostics (smartphone, tablet, etc.
General presentation (continued) Simple and flexible, sustainable Simple and flexible (continued) ew Ren What are my options? How do I operate and maintain? Op e ra b Add or remove discrete and analog I/O modules on RIO drop (not time-stamped) b Add a new RIO drop a ll 2 How do I install and commission? st Life Cycle Services How do I optimize? Change configuration on the fly without stopping the process In Optimize How do I renew my solution? an Pl 1 Modicon M580 automation platform te
General presentation nal Intell i tio nce ge Oper a (continued) Modicon M580 automation platform Winning associations in PlantStruXure architecture Winning associations in PlantStruXure architecture Modicon M580 Ethernet PACs have strong associations with: Partners > > 1 Able to develop X80 modules on Ethernet backplane with Ethernet tool kit backplane For specific applications or communication modules: weighing, Wi-Fi, etc.
Presentation Modicon M580 automation platform Presentation 1 2 The Modicon M580 automation platform is composed of the following devices: b A BMEP58pppp processor b A Modicon X80 I/O platform b Dedicated modules (HART, weighing, etc.
Presentation (continued) Modicon M580 automation platform Dedicated modules HART integrated analog I/O modules The Highway Addressable Remote Transducer (HART) protocol is the global standard for sending and receiving digital information across analog wires between smart devices and a control or monitoring system. The standard is controlled by the HART Communications Foundation. HART integrated analog I/O modules can be added on the backplane of the Modicon M580 processor.
Presentation (continued) Modicon M580 automation platform Cybersecurity ready 1 Achiles Level 2 certification 2 3 Note: For further information, please consult our website www.schneider-electric.com. PF122547 Processor performance The M580 processor supports 4 to 8 local racks (depending on the CPU performance level), using existing X80 I/O modules and accessories. The M580 processor must be installed in the main rack, which can be a dual (Ethernet + X-bus) bus rack.
Modicon M580 automation platform Presentation (continued) Various architectures The Modicon M580 ePAC offers different embedded networks to meet various architecture needs: b Standard Ethernet DIO ports on BMEP58pp20 processors for architectures A, B and C b Dual Ethernet RIO ports on BMEP58pp40 processors for architecture D Architecture A: Composed of hard-wired I/O; mainly compact topology 1 Architecture B: Composed of devices distributed over fieldbuses; mainly compact topology 2 Modicon M580 main
Presentation (continued) Modicon M580 automation platform Ethernet backplane The M580 dual backplanes provide X-bus connection and Ethernet connectivity. One Ethernet switch is embedded in the backplane with connectivity to some slots on the backplane. Not all slots have Ethernet connectivity in the case of 12-slot backplanes.
Presentation (continued) Modicon M580 automation platform Design and setup of Modicon M580 applications Unity Pro Unity Pro programming software u V8.0 is required to set up the Modicon M580 automation platform (see page 4/18).
Modicon X80 I/O platform Compatibility Product compatibility according to the network architecture Product type Reference 1 Local rack Modicon M340 EIO Quantum drop with Modicon X80 EIO drop with CRA drop adaptor type Local rack Modicon M580 M580 EIO drop with X-bus BMXXBP backplane and CRA drop adaptor type Single-rack or multi-rack “standard” BMXCRA31200 X-bus BMXXBP rack “standard” BMXCRA31200 “performance” BMXCRA31210 Ethernet + X-bus BMEXBP rack “performance” BMXCRA31210 M580 EIO drop
Modicon X80 I/O platform Compatibility (continued) Product type Product compatibility according to the network architecture Reference 1 Local rack Modicon M340 EIO Quantum drop with Modicon X80 EIO drop with CRA drop adaptor type Local rack Modicon M580 M580 EIO drop with X-bus BMXXBP backplane and CRA drop adaptor type Single-rack or multi-rack “standard” BMXCRA31200 X-bus BMXXBP rack “standard” BMXCRA31200 “performance” BMXCRA31210 Ethernet + X-bus BMEXBP rack “performance” BMXCRA31210 M5
Modicon M580 automation platform Selection guide Modicon M580 processors Modicon M580 platform for Unity Pro software offer BMEP5810 model BMEP5820 models BMEP5830 models BMEP5840 models 1 1 2 2 Racks I/O 3 In-rack applicationspecific channels 4 5 4 Remote I/O drop of 2 racks – – Maximum number of discrete I/O channels (1) 1,024 2,048 3,072 4,096 Maximum number of analog I/O channels (1) 256 512 768 1,024 Maximum number of Ethernet DIO devices 64 128 Maximum number of applicat
Presentation Modicon M580 automation platform Processor modules Presentation The Modicon M580 BMEP58 modular processors form the core of a complete control solution based on Modicon M580 specific and compatible modules and racks. These standalone processors physically occupy two module slots (0 and 1) on a backplane. 1 2 Modicon M580 configuration 3 The processors can manage the Modicon X80 I/O platform in a single-rack or multi-rack Ethernet PAC station.
Modicon M580 automation platform Presentation Processor modules 8 Description of BMEP58pppp processors 7 1 6 2 3 5 4 BMEP58pppp BMEP58pppp processors include : 1 A display block comprising 7 LEDs whose varying combinations provide a quick diagnostic status of the processor: b RUN LED (green): processor in operation (program execution) b ERR LED (red): processor or system detected error b I/O LED (red): detected I/O module fault b DL LED (green): firmware download is in progress b BACKUP LED (red): b
Modicon M580 automation platform Memory structure Processor modules M580 processor 1 Internal application RAM Program Data 2 Optional memory card Write-protect switch Persistent memory Application program 3 %MW backup Saved data 4 Modicon M580 application storage Memory structure Internal memory capacity The internal application RAM of Modicon M580 processors stores and executes the application program.
Modicon M580 automation platform References Processor modules Modicon M580 processors PF122552 I/O capacity Maximum number of networks 2 Ethernet networks Device ports Service port Reference 2 DIO 1 BMEP581020 0.849/ 1.872 2,048 discrete I/O 512 analog I/O 32 application-specific channels 8 MB integrated (memory program) 2 Ethernet networks 2 DIO 1 BMEP582020 0.849/ 1.872 2 RIO/DIO 1 BMEP582040 0.849/ 1.
Modicon M580 automation platform Presentation, description M580 backplanes Presentation The M580 PAC is complatible with two types of backplane: dual Ethernet and X-bus backplanes or X-bus only backplanes (1)(2). One Ethernet switch is embedded in the backplane with connectivity to some slots on the backplane (not all slots have Ethernet connectivity). X-bus functionality is preserved and conforms to the legacy implementation and specification.
Modicon M580 automation platform Description, references M580 backplanes Description (continued) 10 9 12 11 10 BMXXSPpp00 cable shielding connection kit Cable shielding connection kit To be ordered separately: A BMXXSPpp00 cable shielding connection kit, used to help protect against electrostatic discharge when connecting the shielding on cordsets for connecting: b Analog, counter, and motion control modules b Some Magelis HMI terminals (1) to the processor (via BMXXCAUSBH0pp shielded USB cable) Th
Modicon M580 automation platform Presentation Multi-rack configuration 1 4 1 2 2 3 4 Composition of an expansion backplane configuration M580 CPU supports 4 to 8 local racks (depending upon the CPU performance level), using existing X80 I/O modules and accessories. A Modicon M580 CPU must be installed in the first rack (#0) and this can be a dual bus rack. A Modicon M580 PLC will support up to 7 BMXXBPpppp PV02 or higher backplanes (racks) of 4, 6, 8, or 12 slots.
Modicon M580 automation platform Description Multi-rack configuration Modicon X80 expansion rack Modicon M580 X-bus Premium racks Premium X-bus expansion example Premium X-bus expansion - making migration as simple as possible Modicon M580 CPU supports revamping of an existing Premium installation by replacing the Premium rack 0 (CPU and communication modules) with an M580 rack. It is also possible to associate TSXRKY4EX/6EX/8EX/12EX Premium racks with X80 I/O based on an X-bus rack.
References Modicon M580 automation platform Multi-rack configuration 1 PF106104 Expansion racks 2 Type of module to be inserted No. of slots (1) Power consumption (2) Reference X-bus backplanes for expansion racks (3) Modicon X80 I/O modules (3) BMEP58 processors 4 1W BMXXBP0400 0.630/ 1.389 6 1.5 W BMXXBP0600 0.790/ 1.742 8 2W BMXXBP0800 0.950/ 2.094 12 0W BMXXBP1200 1.270/ 2.
Modicon M580 automation platform References Multi-rack configuration Cordsets and connection accessories PF108142 Description X-bus extension cordsets total length 30 m/98.425 ft. max. Use Composition Type of Length connector m/ft. Reference Between 2 BMXXBE1000 rack expansion modules 2 x 9-way SUB-D connectors Angled 0.8/2.625 BMXXBC008K 1.5/4.921 BMXXBC015K 3/9.842 BMXXBC030K 5/16.404 BMXXBC050K 12/39.37 BMXXBC120K 1/3.281 TSXCBY010K 3/9.842 TSXCBY030K 5/16.
1 2 3 4 5 6 7 8 9 10 2/0
Contents 2 - I/O architectures Architectures Overview of I/O architectures……………………………….…………. . . . . page 2/2 b Presentation …………………………………..….…………………... ........ page 2/4 1 b Architecture A………………….……………..….…………………... ......... page 2/5 b Architecture B………………….……………..….…………………............ page 2/6 b Architecture C………………….……………..….……….…………........... page 2/7 b Architecture D………………….……………..….…………………............ page 2/8 b Modicon X80 performance EIO adapter……................. ….…………...
Modicon M580 automation platform Overview I/O architectures 1 Modicon M580 type of architecture Note: These architectures can be combined with each other Architectures with local racks (main rack and expansion racks) Architecture with local racks (main rack and expansion racks) Architecture with racks in remote drops Hardwired Distributed peripherals over fieldbuses Distributed peripherals and I/O over Ethernet Remote over Ethernet Compact topology with devices hardwired on local I/O Compact to
Modicon M580 automation platform Presentation I/O architectures Presentation The Modicon M580 automation platform offers four different types of architectures with local racks or with racks in remote drops. These four options are presented on the following pages as architectures A, B, C and D.
Modicon M580 automation platform Presentation (continued) Architectures with local racks Architecture A Presentation Main rack Architecture A is used for control systems that reside in the main control cabinet. The M580 platform provides interrupt services for this type of application. X-bus Up to 94 slots are possible for I/O modules in a configuration comprising a main rack and 7 expansion racks, connected by BMXXBEp00p rack expansion modules.
Modicon M580 automation platform Presentation, description Architectures with local racks Architecture B 1 2 3 Presentation 5 Architecture B is based on architecture A with the possibility of adding fieldbuses such as AS-Interface, Modbus SL, HART, etc. 1 Architecture B is used for control systems that are wired to the main control cabinet. It consists of a mainly local topology with several peripherals distributed over fieldbuses.
Modicon M580 automation platform Presentation, description (continued) Architectures with local racks Architecture C Presentation Main rack 1 Architecture C consists of I/O and devices distributed over Ethernet (DIO). The Ethernet DIO devices can be connected to Ethernet ports of the BMEP58p0p0 CPU 1 or of a ConneXium DRS (Dual Ring Switch) switch. 7 Ethernet Distributed I/O 6 4 2 2 Modbus serial link devices can be integrated in architecture C via the BMXNOM0200 serial link module.
Modicon M580 automation platform Presentation, description (continued) Architectures with remote racks Architecture D Presentation Architecture D consists of remote I/O and remote functions (including fieldbus masters). 1 Main rack Remote drop The available Ethernet devices are: 2 b Variable speed drives 2 b Energy supervision 3 and HMI 4 b Tesys T motor protection, etc.
Modicon M580 automation platform Presentation, description (continued) Modicon X80 performance EIO adapter Modicon X80 performance EIO adapter Presentation An M580 Ethernet RIO (EIO) architecture with Modicon X80 I/O drops requires the use of a dedicated adapter in each Modicon X80 drop. 1 The BMECRA31210 adapter supports Ethernet and X-bus communications across the remote backplane.
Presentation, functions, description Modicon M580 automation platform Modbus/TCP and EtherNet/IP network module Presentation The BMXNOC0402 (1) network module acts as an interface between the M580 PLC and other Ethernet network devices via the Modbus/TCP and EtherNet/IP communication protocols. 1 The standard format BMXNOC0402 network module occupies a single slot in the rack of the Modicon M580 platform. This module should be installed in the main Ethernet backplane rack.
Modicon M580 automation platform Presentation, description Modicon X80 NRP EIO drop optical repeaters, ConneXium managed switches Modicon X80 EIO drop optical repeaters (1)(2) Presentation BMXNRP0200/0201 optical fiber repeaters are an alternative to the use of ConneXium managed dual ring switches (DRS), for optical fiber communications over long distances, in Ethernet I/O (EIO) systems.
Modicon M580 automation platform Architectures I/O architectures Example of a complex architecture Example of a complex architecture 1 2 The complex architecture below illustrates the extensive possibilities of the Modicon M580 offer: b A choice between 7 BMEP58p0p0 CPUs 1 b Easy integration of the I/O network with supervisors in the control network, due to the BMXNOC0402 Ethernet module 2 (1) b Optimized wiring with RIO and DIO control via a single medium: the DIO are controlled via the CPU b High ava
Modicon M580 automation platform Architectures I/O architectures Example of an architecture Example of an architecture for Food & Beverage applications Control network 1 Control network Modicon M580 main rack Modicon M580 main rack 2 Modicon X80 remote drop STB I/O island Ethernet STB I/O island Variable speed drive Power meter for energy management on Modbus SL 3 Motor protection STB I/O island Power meter ConneXium managed switch (DRS) Ethernet Motor starter on CANopen Modicon X80 remot
Modicon M580 automation platform Architectures I/O architectures Example of an architecture Example of an architecture for a Water application 1 Control network Modicon M580 main rack 2 Remote Terminal Unit Modicon X80 drop Hardwired equipment Power meter on Ethernet SERVICE port of the BMECRA31210 module Modbus SL Modicon X80 drop Ethernet 3 HMI Local HMI on Ethernet SERVICE port of BMECRA31210 module Energy supervision Variable speed drive 4 Modicon X80 drop 5 HART instrumentation mana
Modicon M580 automation platform Architectures I/O architectures Example of an architecture Example of an architecture for a Hydro power application 1 Control network Modicon M580 main rack 2 Ethernet Modicon X80 remote drop 3 Modicon X80 long distance remote drop on optical fiber with embedded NRP optical fiber modules 4 Hardwired equipment 5 Modbus SL Distributed equipment connected to a ConneXium managed switch (DRS) mixed on Ethernet RIO main ring 6 7 Example of an architecture: Hydro p
Modicon M580 automation platform Architectures I/O architectures Example of an architecture Example of an architecture for a Cement application 1 Control network Modicon M580 main rack 2 Modicon X80 drop Optical fiber 3 Modicon X80 drop 4 Ethernet iMCC Modicon X80 drop 5 Distributed equipments on Ethernet Profibus Remote Master Profibus DP Profibus PA HMI 6 Local HMI on Ethernet SERVICE port of BMECRA31210 module Example of an architecture: Cement application 7 8 9 10 Processors: page 1
Modicon M580 automation platform References I/O architectures 5 References (1) Ethernet head and drop adapters (2) 1 Description Modicon X80 EIO drop adapter Provide 1 module per Modicon X80 EIO drop 1 Ethernet 7 9 Item Reference (3) Weight kg/lb – 1 BMXCRA31200 0.200/ 0.441 1 1 BMXCRA31210 (4) 0.234/ 0.516 1 1 BMECRA31210 (4) 0.234/ 0.
Modicon M580 automation platform References (continued) I/O architectures 5 References (continued) (1) 1 Modicon M580 processors 1 I/O capacity 1 1,024 discrete I/O 256 analog I/O 24 application-specific channels 4 MB integrated (memory program) Ethernet 2 7 9 9 3 X-bus 8 Architecture A + architecture D 4 5 CANopen 2,048 discrete I/O 512 analog I/O 32 application-specific channels 8 MB integrated (memory program) 2 Ethernet networks 3,072 discrete I/O 768 analog I/O 64 application-spe
Modicon M580 automation platform References (continued) I/O architectures References (continued) (1) Description X-bus preformed extension cordsets with two 9-pin SUB-D connectors Type of connector Elbowed Straight Description Use Length m/ft Item (2) Reference Weight kg/lb 0.8/2.625 8 BMXXBC008K 0.165/ 0.364 1.5/4.921 8 BMXXBC015K 0.250/ 0.551 3/9.843 8 BMXXBC030K 0.420/ 0.926 5/16.404 8 BMXXBC050K 0.650/ 1.433 12/39.370 8 BMXXBC120K 1.440/ 3.175 1/3.281 8 TSXCBY010K 0.
Selection guide Type of splitter box and module 1 Modicon distributed I/O solutions Monobloc IP 67 I/O splitter boxes Monobloc IP 20 distributed I/O Optimum IP 20 distributed I/O Modular IP 20 distributed I/O Modicon ETB Modicon Momentum Modicon OTB Modicon STB 1 2 2 3 3 4 5 6 Available buses and networks Ethernet Modbus TCP/IP EtherNet/IP Max.
Presentation Modicon STB distributed I/O solution Open and modular system Presentation (1) To meet the needs of machine manufacturers and users, automation architectures have been decentralized while delivering performance close to that of centralized systems. 1 Architectures based around islands installed as close to the machine as possible reduce the time and cost of wiring for sensors and actuators, while increasing system availability.
Modicon STB distributed I/O solution Description Open and modular system Modicon STB modules (1) The Modicon STB module references allow you to acquire the following items under a single reference: b A module b Its base b The appropriate screw-type and/or spring-type connectors The following table gives the contents of the Modicon STB modules and the general form of their references (1).
Composition Modicon STB distributed I/O solution Open and modular system Composition of a Modicon STB island (1) A Modicon STB island is made up of one or more segments comprising PDMs (Power Distribution Modules) and I/O modules. The island begins with a NIM network interface module and ends with a bus terminator supplied with the NIM. An island can be made up of a single segment or a primary segment and up to 6 expansion segments.
Modicon STB distributed I/O solution Configurations Open and modular system Control system configuration example (1) NIM network interface modules STBNpp2p1p, located at the beginning of each island, are gateways for exchanging data between the network or bus master PLC and the Modicon STB automation island. Standard NIM network interface modules STBNpp2p1p can be used to configure and address the installation external devices. These settings are stored in the module’s internal RAM or Flash memory.
1 2 3 4 5 6 7 8 9 10 3/0
Contents 3 - Communication Communication selection guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3/2 PlantStruxure Ethernet architectures b Architecture ........................................................................................... page 3/6 1 b Industrial Ethernet communication services ...................................... page 3/8 v Presentation ............................................................................................ page 3/8 v Functions..
Selection guide Modicon M580 automation platform Communication, integrated ports and modules Applications Ethernet communication Ethernet communication RTU communication Type of device Processors with integrated Modbus/TCP port Ethernet modules RTU module Network protocols 3 Structure EtherNet/IP and Modbus/TCP Physical interface Modbus/TCP, IEC 60870-5-104, DNP3 (subset level 3) Serial link, external modem link, IEC 60870-5-101, DNP3 (subset level 3) 10BASE-T/100BASE-TX (Modbus/TCP), PPPoE
Selection guide (continued) Modicon M580 automation platform Communication, integrated ports and modules 3 Applications AS-Interface communication Serial link communication Modbus Plus communication Profibus DP and Profibus PA communication Type of device AS-Interface actuator/sensor bus module 2-channel serial link module Modbus Plus proxy module (external) Profibus Remote Master (PRM) module (external) Network protocols Structure AS-Interface Ethernet Modbus/TCP Modbus Plus Ethernet Modb
Modicon M580 automation platform Architecture 0 PlantStruxure Ethernet architectures Logical communication architecture Logical communication architecture 1 Company Intranet Internet Site 3 3 Site 2 Enterprise Site 1 MES ERP Unix Windows Linux Ethernet Modbus/TCP and EtherNet/IP 2 Factory HMI + SCADA 4 Industrial PC Workshop M580 M580 M580 5 Premium 6 Premium Premium Modicon M340 HMI PLC 7 Momentum M1E Collaborative Automation Partner Program Robot Distributed I/O 8 Variab
Modicon M580 automation platform Architecture (continued) 0 PlantStruxure Ethernet architectures Physical communication architecture Physical communication architecture Site 3 Router Router Site 2 Internet Provider WAN Provider 2 Site 1 Public telecommunications network, ADSL Specialized link Frame Relay ATM Router 1 RAS Firewall 3 Switches (VLAN) or routers Switch Switch Switch 100BASE-FX Full Duplex Switch Collision domain 2 Quantum Premium Switch Optical fibers Half Duplex 100 m
Modicon M580 automation platform Presentation PlantStruxure Ethernet architectures Industrial Ethernet communication services Presentation PlantStruxure Ethernet architectures provide transparent communication services to the entire operation through the implementation of standard, unmodified Ethernet protocols and services.
Modicon M580 automation platform Functions PlantStruxure Ethernet architectures Industrial Ethernet communication services Functions Ethernet basic services HTTP (RFC 1945) HTTP (HyperText Transfer Protocol) is used to transmit Web pages between a server and a browser. HTTP has been used on the Web since 1990. Web servers embedded in Schneider Electric automation products provide easy access to information and diagnostics from anywhere in the network.
Modicon M580 automation platform Functions (continued) PlantStruxure Ethernet architectures Industrial Ethernet communication services 1 2 Modbus/TCP function codes Bit Read n input bits access Read n output bits Read exception status Write 1 output bit Write n output bits Read 1 input word Read n input words Write 1 output word Write n output words Read device ID dec 02 01 07 05 15 04 03 06 16 43/14 hex 02 01 07 05 0F 04 03 06 10 2B/0E Examples of Modbus/TCP function codes for accessing data and di
Functions (continued) Modicon M580 automation platform PlantStruxure Ethernet architectures Industrial Ethernet communication services Functions (continued) EtherNet/IP standard communication protocol 1 EtherNet/IP is an industrial communications protocol based on the Common Industrial Protocol (CIP) which is owned and managed by the ODVA, an international, independent standards organization (www.odva.org). Standard, unmodified Ethernet Schneider Electric added EtherNet/IP as a core network in 2007.
Functions (continued) Modicon M580 automation platform PlantStruxure Ethernet architectures Ethernet Modbus/TCP communication services Functions (continued) I/O Scanning service 1 Word table Read Modicon Premium, M580 or Quantum platform with I/O Scanner function (Transparent Ready class p30) Write 2 Ethernet Modbus/TCP 3 Device with Modbus/TCP messaging in server mode Device input words/ output words 4 INPUT OUTPUT + – A B INPUT OUTPUT + – A B The I/O Scanning Service is used to manage
Functions (continued) Modicon M580 automation platform PlantStruxure Ethernet architectures Ethernet Modbus/TCP communication services Functions (continued) FDR (Fast Device Replacement) service The Fast Device Replacement service uses standard address management technologies (BOOTP, DHCP) and the TFTP (Trivial File Transfer Protocol) file management service, with the aim of simplifying maintenance of Ethernet devices.
Modicon M580 automation platform Performance Ethernet Modbus/TCP network Performance Selecting the communication architecture When selecting an architecture, performance needs to be taken into account at the earliest possible stage.
Modicon M580 automation platform Performance (continued) Ethernet Modbus/TCP network Performance Event Application response time Report Modbus (or Uni-TE) messaging service response time TT CT1 CT1 Station 1 CT1 CT1 NAT NAT CT2 CT2 Station 2 Action Exchanges between the PLC CPU and the Ethernet module are synchronous with the PLC scan cycle time (CT), just like the I/O exchanges.
Modicon M580 automation platform Performance (continued) Ethernet Modbus/TCP network Performance Application response time (continued) 1 CT Manager Ethernet Modbus/TCP RT Hub Input Device 1 2 Output Device 2 I/O Scanning service response time The response time RT includes the time between taking account of information from a remote input and updating the state of a remote output. It includes the processing time in the PLC.
Performance (continued) Modicon M580 automation platform Ethernet Modbus/TCP network Performance Application response time (continued) I/O Scanning service response time (continued) 1 Below are the TMod In and TMod Out response times: Type of distributed I/O Momentum 170ENT11002 Response time TMod In TMod Out TMod In TMod Out TMod In TMod Out Momentum 170ENT11001 Advantys STB STBNIP2212 Min. 1 ms 5 ms 4 ms 4 ms 2 ms 2 ms Typical 1 ms 5 ms 6 ms 6 ms 3 ms 3 ms Max.
Performance (continued) Modicon M580 automation platform Ethernet Modbus/TCP network Performance Processing capacities of Modicon platforms Processing capacity 1 Use the table below to compare, for each station, the total number of messages received via the Modbus (or Uni-TE) messaging service if used (value R1, R2, or Ri) with the capacity of the station CPU.
Modicon M580 automation platform Performance (continued), selection Ethernet Modbus/TCP network Performance Processing capacities of Modicon platforms (continued) Number of simultaneous TCP/IP connections The number of simultaneous TCP/IP connections depends on the platform as well as the type of connection to the Ethernet network: b 10/100BASE-TX port in network modules b 10/100BASE-TX port integrated in CPUs Number of simultaneous TCP/IP connections Client Server Modicon M340 BMX NOC0401 P342020 NO
Presentation Modicon M580 automation platform Embedded web pages The M580 CPU includes a Hypertext Transfer Protocol (HTTP) server. The server transmits web pages for the purpose of monitoring, diagnosing, and controlling remote access to the communication module. The server provides easy access to the CPU from standard internet browsers. 1 The embedded web server pages are used to display real-time diagnostic data for the M580 CPU.
Presentation (continued) Modicon M580 automation platform Embedded web pages Diagnostic web pages (continued) Performance page 1 The objects on this page provide information on performance statistics.
Presentation (continued) Modicon M580 automation platform Embedded web pages 1 Messaging 2 Diagnostic web pages (continued) Messaging page This page shows current information for open TCP connections on port 502: b Messaging Statistics: This field contains the total number of sent and received messages on port 502. These values are not reset when the port 502 connection is closed. Therefore, the values indicate the number of messages that have been sent or received since the module was started.
Presentation (continued) Modicon M580 automation platform Embedded web pages Diagnostic web pages (continued) Redundancy page This page displays values from the RSTP configuration in Unity Pro.
Modicon M580 automation platform Presentation, functions, description Modbus/TCP and EtherNet/IP network module Presentation The BMXNOC0402 (1) network module acts as an interface between the M580 PLC and other Ethernet network devices via the Modbus/TCP and EtherNet/IP communication protocols. 1 The standard format BMXNOC0402 (1) network module occupies a single slot in the rack of the Modicon M580 platform. This module has to be installed in the main Ethernet + X-bus backplane rack.
Modicon M580 automation platform References Modbus/TCP and EtherNet/IP network module References Description EtherNet/IP, Modbus/TCP network module Data rate Reference 10/100 Mbps BMXNOC0402 (1)(2) Weight kg/lb 0.345/ 0.761 (1) The Unity Pro configuration tool is supplied on CD-ROM with the module. This software is used to update the Unity Pro hardware catalog (addition of the new module DTMs).
Selection guide Modicon M580 automation platform Web servers and gateways 1 Applications Standalone Web Gateway/Server module for remote access Standalone Web Gateway/Server modules for remote access Type FactoryCast Gateway ETG10p0 FactoryCast HMI Gateway ETG30pp 1 2 3 2 Target products Type Any device supporting Modbus Network/Remote access services Remote access Intranet or via external modem and integrated Intranet or modem, external modem and RAS function integrated RAS function Remote
Modicon M580 automation platform Presentation Modbus Plus Proxy module Presentation The TCSEGDB23F24FA Modbus Plus Proxy module is a network gateway that allows Modicon M340 and M580 PLCs to communicate with existing Modbus Plus devices.
Modicon M580 automation platform References Modbus Plus Proxy module Embedded Web server Web server functions The Modbus Plus Proxy module includes an embedded Web server that can be used to perform diagnostics and configure the module connection. All data is presented in the form of standard Web pages in HTML format. To access a Web page, you need Internet Explorer (version 6.0 or later) and Java (version 1.5 or later).
Modicon M580 automation platform Presentation Profibus DP V1 and Profibus PA buses Profibus Remote Master module Profibus DP fieldbus Profibus DP is one of the most widely used fieldbuses in industry. Based on a master/slave protocol, only master stations, sometimes called active stations, have the right to access the bus, with slave, or passive, stations being limited to responding to interrogations.
Presentation (continued), references Modicon M580 automation platform Profibus DP V1 and Profibus PA buses Profibus Remote Master module Profibus Remote Master (PRM) module (continued) Connectable devices 1 The following Schneider Electric devices can be connected to this bus: b TeSys U and TeSys T starter-controllers b Momentum and Modicon STB distributed I/O b Altivar 312/61/71 variable speed drives for asynchronous motors b Lexium 05 and 32 servo drives for brushless motors b Altistart ATS 48 soft s
1 2 3 4 5 6 7 8 9 10 4/0
Contents 4 - Software Unity Pro software Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4/2 b Presentation........................................................................................... page 4/4 1 b FDT/DTM................................................................................................. page 4/4 b Programming languages ...................................................................... page 4/5 b Functions ...
Selection guide Software Unity Pro software Unity Pro programming software for Modicon M340 M, Modicon M580 M5, Premium P, Quantum Q, Safety S and Modicon distributed I/O D platforms Unity Pro programming software for Modicon M340 M , Modicon M580 M5, Premium P, Quantum Q, Safety S and Modicon distributed I/O D platforms 1 2 3 4 5 6 1 IEC 61131-3 Instruction List (IL) languages Ladder (LD) Structured Text (ST) Function Block Diagram (FBD) Sequential Function Chart (SFC)/Grafcet Ladder Logic Language L
Presentation, functions Software Unity Pro software Small/Large/Extra Large Presentation Unity Pro is the common programming, debugging and operating software for the Modicon M340, M580, Premium and Quantum PLC ranges. 1 Unity Pro 2 3 FDT/DTM function Unity Pro facilitates integration of fieldbus architectures into engineering control systems using FDT/DTM technology: b FDT (Field Device Tool) is the container which supports the device DTMs.
Functions (continued) Software Unity Pro software Small/Large/Extra Large FDT/DTM function (continued) The fieldbus lookup function scans the physical devices in a fieldbus network and adds the selected devices to the DTM Browser. 1 2 3 Fieldbus lookup screen Programming languages The five IEC 61131-3 compliant languages The five graphical or textual languages available in Unity Pro are used for programming Modicon M340, Modicon M580, Premium and Quantum automation platforms.
Functions (continued) Software Unity Pro software Small/Large/Extra Large Data editor The data editor provides a single tool for performing the following editing tasks: b Declaration of data including variables and function blocks (declaration of their type, instances and attributes). b Use and archiving of function block data types in different libraries. b Hierarchical view of data structures. b Searching, sorting and filtering of data.
Functions (continued) Software Unity Pro software Small/Large/Extra Large DFB user function blocks With Unity Pro software, users can create their own function blocks for specific application requirements on Modicon M340, Modicon M580, Premium and Quantum platforms. 1 Once created and saved in the library, these user function blocks can be reused as easily as EFBs (Elementary Function Blocks). Design The user function blocks can be used to structure an application.
Functions (continued) Software Unity Pro software Small/Large/Extra Large Function block libraries 1 2 3 Standard function block libraries The function and function block libraries manager contains the elements provided with Unity Pro software. Functions and function blocks are organized into libraries, which themselves consist of families. Depending on the type of PLC selected and the processor model, users will have a subset of these libraries available to write their applications.
Functions (continued) Software Unity Pro software Small/Large/Extra Large Debugging tools Dynamic animation/adjustment Unity Pro software offers a complete set of tools for debugging Modicon M340, M580, Premium or Quantum applications. A tool palette provides direct access to the main functions: b Dynamic program animation. b Setting of watchpoints or breakpoints (not authorized in event-triggered tasks). b Step-by-step program execution. A function in this mode enables section-bysection execution.
Functions (continued) Software Unity Pro software Small/Large/Extra Large PLC simulator 1 Simulator control panel 2 Unity Pro’s integrated simulator can be used to test the application program for Modicon M340, M580, Premium or Quantum PLCs from the PC terminal without having to connect to the PLC processor. The functions provided by the debugging tools are available for debugging the master, fast and auxiliary tasks.
Software Functions (continued) Unity Pro software Small/Large/Extra Large Integrated diagnostics Diagnostics integrated in Modicon M340, Modicon M580, Premium and Quantum automation platforms Presentation System diagnostics 1 Diagnostics viewers Vijeo Citect Thin client Magelis iPC Processor for system bits and words In-rack I/O modules Higher-level M.E.S.
Functions (continued) Software Unity Pro software Small/Large/Extra Large Modifying the program with the PLC in RUN mode With Unity Pro, changes can be made to the program when the PLC connected to the programming terminal is in RUN mode. These modifications are performed with the following operations: b The application contained in the PLC is transferred to the PC terminal running Unity Pro, if necessary. b Program changes are prepared.
Functions (continued) Software Unity Pro software Small/Large/Extra Large Application converters Unity Pro’s integrated conversion tools can be used to convert PLC applications created with ModSoft, ProWorX, Concept and PL7 programming software to Unity Pro applications. 1 Concept/Unity Pro converter (Quantum PLC) This conversion is performed with a Concept application V2.5 or later (it can also be performed in V2.11 or later, but only after an update to V2.5).
Software Functions (continued) Unity Pro software Small/Large/Extra Large Programmable process control Process control in machines Unity Pro contains CONT_CTL, a library of 36 function blocks used to create control loops for machine control.
Functions (continued), Software Unity Pro software Small/Large/Extra Large Programmable process control Process control in machines (continued) CONT_CTL library functions (continued) Process value processing AVGMV AVGMV_K DEAD_ZONE LOOKUP_TABLE1 Moving average with fixed number of samples (50 max.) Moving average with constant correction factor, 10,000 samples max.
Functions (continued) Software Unity Pro software Small/Large/Extra Large Communication drivers The most commonly used communication drivers for Modicon M340, M580, Premium and Quantum platforms are installed at the same time as the Unity Pro software.
Functions (continued) Software Unity Pro software Small/Large/Extra Large Unity Pro update Customers are notified automatically when a new Unity Pro update becomes available. They can then access the software updates manager directly, download the update and install it locally on their workstation. 1 2 3 4 5 Note: The latest firmware versions can be downloaded from our website www.schneider-electric.com.
References Software Unity Pro software Small/Large/Extra Large References 1 Unity Pro Unity Pro software packages These software packages are for programming and setting up Unity automation platforms. The software is available in three versions: b Unity Pro Small UNYPROSP80 (see page 4/18). b Unity Pro Large UNYPROLP80 (see page 4/19). b Unity Pro Extra Large UNYPROXLP80 (see page 4/20).
References (continued) Software Unity Pro software Small/Large/Extra Large Unity Pro Large version 8.0 software For Modicon M340: All models For Modicon M580: BMEP5810/5820/5830 For Modicon Premium: TSX571p…4p For Modicon Quantum: 140CPU31110/43412U/53414U For distributed I/O: Modicon ETB, TM7, OTB, STB, Momentum 1 Unity Pro Large version 8.
References (continued) Software Unity Pro software Small/Large/Extra Large Unity Pro Extra Large version 8.0 software 1 Unity Pro For Modicon M340: All models For Modicon M580: All models For Modicon Premium: TSX571p...6p For Modicon Quantum: 140CPU31110/43412U/53414U/65150/65160/65260/67160/67260/67261 For distributed I/O: Modicon ETB, TM7, OTB, STB, Momentum Unity Pro Extra Large version 8.
References (continued) Software Unity Pro software Small/Large/Extra Large Accessories for connecting to the PC programming terminal Description Use From processor port BMXXCAUSBH0pp To PC port Length Reference m/ft PC terminal USB mini B port USB port connection BMXP341000/20p0/20p02 cables BMEP58pppp (PC to PLC) (1) RS 232D Mini-DIN port Premium TSX571p/2p/3p/4p (9-way SUB-D connector) 1.8/ 5.91 BMXXCAUSBH018 0.065/ 0.143 4.5/ 14.8 BMXXCAUSBH045 0.110/ 0.243 2.5/ 8.20 TSXPCX1031 0.
Presentation, setup Software Unity Pro software Unity EFB Toolkit software Presentation 1 Unity EFB Toolkit Unity EFB Toolkit is the software for developing EFs and EFBs in “C” programming language. As an option with Unity Pro, it can be used to extend the standard Unity Pro function blocks in order to increase functionality. This software comes with Microsoft Visual Studio, which can be used to debug the function blocks developed in the Unity Pro PLC simulator.
References Software Unity Pro software Unity EFB Toolkit software References Unity EFB Toolkit and its documentation are supplied in electronic format on DVD-ROM in English.
Presentation, setup Software Unity Pro software Unity DIF software Presentation 1 Unity DIF Unity DIF is a companion software for Unity Pro. It compares two Unity Pro applications and displays an exhaustive list of the differences. The differences are displayed graphically and textually based on the type of program/section chosen.
References Software Unity Pro software Unity DIF software References This Unity DIF software is used to compare two Unity applications generated by Unity Pro software version V2.1 or later. 1 Compatibility: All Unity Pro packages and platforms are supported. Description Unity DIF software Language Type Reference English (software and electronic documentation) Single license (1 station) UNYDFFXZZSPA80 Weight kg/lb – (1) 2 (1) Available on our website www.schneider-electric.com.
Presentation Software Unity Pro software Unity Loader software Presentation 1 Unity Loader 2 Unity Loader is companion software to Unity Pro and is used to perform maintenance operations on automation applications. Its easy setup and the small size of its executable make it a vital tool for updating Unity Pro projects without needing to use Unity Pro. It can also be used for updating the embedded software on Modicon M340, M580 or Momentum Unity PLCs or on Modicon X80 I/O modules.
Presentation (continued), references Software Unity Pro software Unity Loader software Communication between the PC and the PLC Unity Loader Unity Loader supports the following PC-to-PLC communication: b Modicon Quantum Unity Pro PLCs: Modbus communication, transfer of project components only b Modicon Premium Unity Pro PLCs: Unitelway communication, transfer of project components only b Modicon M340, M580 or Momentum Unity PLCs or Modicon X80 I/O modules: communication via Ethernet and USB ports, tra
Presentation Software Unity Pro software Specific libraries Presentation 1 Unity specific Libraries 2 The CONT_CTL process control function block library supplied with Unity Pro software can be supplemented with optional specialized libraries so as to meet specific needs such as: b Predictive control b Fuzzy logic controller b HVAC b Mass flow calculation Fuzzy Control Library This library is used in particular in the water treatment field, for example for controlling chlorine levels in fresh water po
References Software Unity Pro software Specific libraries Specific libraries depending on the software used Specific libraries depending on the software used (see below) can be ordered separately.
Presentation 3 Software 3 OPC data server software OPC Factory Server Presentation Based on the OLE for Process Control (OPC) standard, Schneider Electric's OPC Factory Server (OFS) software allows “client” software applications, such as supervisors/SCADA and customized interfaces, to access the data of Schneider Electric automation system and electrical distribution devices connected to networks or fieldbuses in real time.
Architectures 0 Software 3 OPC data server software OPC Factory Server Supported architectures The OFS server allows four access modes: b A purely local mode b Remote access from an OPC-DA client b Remote access from an OPC.NET client b Remote access from an OPC XML-DA or OPC UA clients b Remote access from an OPC-UA client 1 2 Local access The client application and the OFS server are on the same PC. OFS station OPC Factory Server: Home page Local client applic.
Architectures (continued) 0 Software 3 OPC data server software OPC Factory Server Architectures supported (continued) Remote access from an OPC .NET client 1 The .NET client application program and the OFS data server are on remote stations. Communication between the client station and the OFS server is conducted through the DCOM layer (Microsoft) via the OPC-DA protocol. Intranet 2 DCOM Ethernet Modbus/TCP network Server OFS station .NET client 3 The .
Setup Software 3 3 OPC data server software OPC Factory Server Setup 1 Ethernet Modbus/TCP 1 OFS server (V3.0) 4 Database Unity Pro project station Symbols.xvm (Unity Pro) Symbols.prj (Concept) Symbols.scy (PL7) 2 OPC client 2 3 Quantum 3 3 Premium Ethernet Modbus/TCP 3 M580 4 3 M340 The OFS server 1 is at the center of the data exchanges.
Functions 3 Software 3 OPC data server software OPC Factory Server Function Development of client applications 1 OFS software has 4 types of interface: b OLE Automation interface (OPC-DA) Particularly suitable for end users, this enables the development of OPC client applications in Visual Basic, in Visual Basic for Excel, and in C++.
References 3 Software 3 OPC data server software OPC Factory Server References OFS V3.5 software for PC compatible stations (minimum configuration: Pentium 566 MHz processor, 128 Mb of RAM) running Windows® 7 (32-bit or 64-bit) or Windows 8 (32-bit or 64-bit). 1 The OFS V3.
Software Presentation 3 OPC data server software Time stamping system Presentation The time stamping system is a complete solution providing a SCADA with a sequence of events that are time-stamped at source, enabling the user to analyze the source of any abnormal behavior in an automated system. 1 The SOE (sequence of events) is displayed in the alarm log or in the list of events for a client such as a SCADA.
Software Performance 3 OPC data server software Time stamping system Performance Performance Event source module Value Between two identical source modules in the same rack BMXERT1604T 1.6 < resolution < 3.
1 2 3 4 5 6 7 8 9 10 5/0
Contents 5 - Ruggedized Modicon M580 modules Treatment for severe environnements b Presentation........................................................................................... page 5/2 b Harsh chemical environnements ......................................................... page 5/2 1 b Extreme climatic environnements ....................................................... page 5/2 Ruggedized processor modules b References .....................................................................
Modicon M580 automation platform Presentation Treatment for severe environments Ruggedized modules Presentation Protective treatment of Modicon M580 automation platform 1 The Modicon M580 automation platform complies with “TC” treatment requirements (Treatment for all Climates). it is designed as standard to operate in temperatures of 0 to + 60°C/32 to 140°F.
Presentation (continued), references Modicon M580 automation platform Dedicated parts for severe environments Ruggedized processor modules Composition References and characteristics 1 To order ruggedized modules and racks, see the reference pages 5/3 to 5/5 (the references of the ruggedized products available include the suffix “H”). The standard separate parts (cordsets, cables, sub-bases, etc.
Modicon M580 automation platform References Dedicated parts for severe environments Ruggedized racks and rack expansion module Ruggedized racks Description PF106104 1 Ruggedized X-bus racks Type of module to be inserted PF122507B BMEXBP0800H 1W BMXXBP0400H 0.630/ 1.389 1.5 W BMXXBP0600H 0.790/ 1.742 8 2W BMXXBP0800H 0.950/ 2.094 12 – BMXXBP1200H 1.270/ 2.800 2.8 W BMEXBP0400H 0.715/ 1.576 3.9 W BMEXBP0800H 1.070/ 2.359 3.9 W BMEXBP1200H 1.387/ 3.
Modicon M580 automation platform References (continued) Dedicated parts for severe environments Connection accessories, ruggedized communication module and network gateway Connection accessories PF108138 Description TSXTLYEX Use Composition Reference Weight kg/lb Line terminator (Sold in lots of 2) Required on both BMEXBP/ BMXXBPppp0H modules at each end of the daisy chain 2 x 9-way SUB-D connectors marked A/ and /B TSXTLYEX 0.050/ 0.
1 2 3 4 5 6 7 8 9 10 6/0
Contents 6 - Standards and certifications Technical appendices b Standards, certifications and environmental conditions ................... page 6/2 b Certifications for automation products and EC regulations ..............
Modicon M580 automation platform Standards and certifications Standards, certifications and environment conditions Standards and certifications The Modicon M580 automation platform has been developed to comply with the principal national and international standards concerning electronic equipment for industrial automation systems. b Requirements specific to programmable controllers: functional characteristics, immunity, resistance, safety, etc.
Modicon M580 automation platform Environment tests Standards, certifications and environment conditions Environment tests Name of test Immunity to LF interference (e) (1) Standards Levels Voltage and frequency variations IEC/EN 61131-2; IEC/EN 61000-6-2; IEC 61000-4-11 0.85...1.10 Un - 0.94...1.04 Fn; 4 steps t = 30 min IACS E10; IEC 61000-4-11 0.80 Un...0.90 Fn; 1.20 Un...1.10 Fn; t = 1.5 s/5 s Direct voltage variations IEC/EN 61131-2; IEC 61000-4-29; 0.85...1.
Modicon M580 automation platform Environment tests (continued) Standards, certifications and environment conditions Environment tests (continued) 1 Name of test Electromagnetic emissions (e) (1) Conducted emission Standards IEC/EN 61131-2; FCC part 15; IEC/EN 61000-6-4; CISPR 11 & 22, Class A, Group 1 150 kHz … 500 kHz: quasi-peak 79 dB (µV/m); average 66 dB (µV/m) 500 kHz … 30 MHz: quasi-peak 73 dB (µV/m); average 60 dB (µV/m) IACS E10 b a/c power (general power distribution zone): 10 kHz … 150 kH
Modicon M580 automation platform Environment tests (continued) Environment tests (continued) Name of test Standards, certifications and environment conditions Standards Levels Immunity to mechanical constraints (1) (power on) Sinusoidal vibrations IEC/EN 61131-2; IEC 60068-2-6 (Fc) IACS E10 IEC 60068-2-6 Shocks Free fall during operation Name of test IEC/EN 61131-2; IEC 60068-2-27 (Ea) IEC/EN 61131-2; IEC 60068-2-32 (Ed Method 1) Standards Basic IEC/EN 61131-2: 5 Hz ... 150 Hz, ± 3.
Technical appendices Automation product certifications EC regulations 1 Some countries require certain electrical components to undergo certification by law. This certification takes the form of a certificate of conformity to the relevant standards and is issued by the official body in question. Where applicable, certified devices must be labelled accordingly. Use of electrical equipment on board merchant vessels generally implies that it has gained prior approval (i.e.
Technical appendices Automation product certifications EC regulations Merchant navy certifications Shipping classification societies 1 Certified Certification pending BV DNV USA ABS France Norway Germany GL (1) (2) (2) (2) (2) (2) (2) (2) (2) KRS Korea LR RINA Great Britain Italy RRR PRS Russia RMRS Russia Poland (2) (2) CCS China 2 Modicon OTB Modicon STB (2) (2) (2) (2) Modicon Telefast ABE 7 ConneXium Magelis PC/GTW Magelis XBT GT Bridge (2) 3 Magelis XBT GK Mag
1 2 3 4 5 6 7 8 9 10 7/0
Contents 7 - Services A dedicated services offer for your installed base b Maintenance and support services ...................................................... page 7/2 b Consultancy services............................................................................ page 7/3 1 b Modernization solutions ....................................................................... page 7/3 b Customization services ........................................................................
Presentation A dedicated services offer for your installed base Schneider Electric, with its experts, products and dedicated tools, provides services such as system design, consultancy, maintenance contracts, modernisation of facilities or delivering projects. 1 The Schneider Electric services offer is structured around several key areas: b Maintenance and support services: v A set of services to help maintain reliability and availability of automated control systems.
Presentation (continued) A dedicated services offer for your installed base Consultancy services M2C (Maintenance and Modernization Consultancy) Professional tools and methods, proven experience of managing obsolescence and updating installed bases, to reduce downtimes and improve performance With our maintenance and modernization consultancy offer, Schneider Electric will help you check the state of your installed base by: b Defining the scope and depth of the analysis in collaboration with you b Collec
1 2 3 4 5 6 7 8 9 10 8/0
Contents 8 - Technical information, index Technical appendices b Ethernet network infrastructure ........................................................... page 8/2 Index 1 b Product reference index........................................................................
Presentation Technical information Ethernet network Infrastructure Presentation The ConneXium Industrial Ethernet offer comprises a complete family of products and tools (including the ConneXium Network Manager (CNM) software tool) required to build the infrastructure of an Industrial Ethernet network. The following pages provide information on network design and component selection.
Topologies Technical information Ethernet network Infrastructure Different network topologies DTE DTE DTE DTE Star topology In a star topology, all devices and Data Terminal Equipment (DTE) are connected though an intermediate device. Ethernet star In an Ethernet star the intermediate device may be a switch. The star is the most commonly used topology in corporate networks and is currently adopted in almost every automation application.
Topologies (continued) Technical information Ethernet network Infrastructure Different network topologies (continued) Daisy chain topology (continued) 1 Limitations of the daisy chain: Limitations of the daisy chain topology in terms of operational integrity of the network and performance metrics are as follows: b Dual port Ethernet devices only support 10 Mbps and/or 100 Mbps operational speeds and must use one or the other.
Technical information Characteristics Ethernet network Infrastructure Distance limitations and number of devices per segment Based on standard 802.3, the distance limits and number of devices in cascade are as follows: Type Maximum segment length (1) Maximum segment length (offered by ConneXium devices) Maximum number of Maximum number of hubs in cascade switches in cascade 10BASE-T 100 m/328.08 ft 100 m/328.08 ft 4 Unlimited 100BASE-TX 100 m/328.08 ft 100 m/328.
Management Technical information Ethernet network Infrastructure Management 1 Ethernet devices in general (end-of-line devices and cabling devices) can be divided into two categories: unmanaged and managed devices. b Unmanaged devices are those devices for which there is no option to configure or control any of the device parameters. b Managed devices are those devices whose parameters can be configured or controlled (managed) and their internal data can be accessed.
Technical information Redundancy Ethernet network Infrastructure Redundancy To develop high availability applications, “redundancy” in the networking infrastructure is the answer. Developers can help avoid losing network segments by implementing a single ring or a coupled ring architecture. 1 Single ring DTE The first level of redundancy is achieved by implementing a single ring. ConneXium switches allow the set up of backbone ring configurations.
Product reference index Index 1 1 BMXXBC050K 110XCA28201 4/21 110XCA28202 4/21 110XCA28203 4/21 170DNT11000 3/31 BMXXBE1000 4 2 3 490NAD91103 3/31 490NAD91104 3/31 490NAD91105 3/31 490NOR00003 2/18 490NOR00005 2/18 9 4/21 990NAA26350 4/21 4 BMEP581020 BMEP581020H BMEP582020 5 BMEP582020H BMEP582040 BMEP582040H BMEP583020 6 BMEP583040 BMEP584020 7 BMEP584040 BMEXBP0400 BMEXBP0400H BMEXBP0800 BMEXBP0800H 8 9 BMEXBP1200 10 2/17 5/5 1/23 2/18 2/19 5/3 1/23 2/18 2/19 5/3 1/
Head Office 35, rue Joseph Monier F-92500 Rueil-Malmaison France The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Schneider Electric Modicon M580 automation platform 14