Product data

25
References (continued)
Modicon
Quantum
Ethernet I/O
automation platform
Ethernet Hot Standby topology
Rack extension for Ethernet RIO drop
Long distance Quantum Ethernet I/O Hot Standby architecture
Managed
switch
Managed
switches
Ethernet RIO
Ethernet DIO device cloud (7)
Ethernet DIO (7)
Ethernet network
Ethernet network
Fiber optic
Ethernet network
Hot Standby linkHot Standby link
Fiber optic
Ethernet network
Quantum
Ethernet
I/O (Primary PLC)
RSTP
RSTP
RSTP
(3)
Managed
switches
Ethernet RIO
Local
HMI (7)
Ethernet network
Quantum Ethernet I/O
(Standby PLC)
RSTP
(3)
3
4
4
8
6
66
66
3
8
9
2
1
2
2
2
2
References (1) (continued)
Quantum
Hot Standby CPUs
Hot Standby
CPU
Memory (max.) Item
(2)
Reference
(3) (4)
Weight
Clock
frequency
RAM Program
(with located
variables)
Program with
PCMCIA card
MHz
MB KB KB kg
266 MHz
(5)
2 1024 7168 8 140CPU67160
4 3072 7168 8 140CPU67261
Fiber optic cable for Hot Standby architecture
Description Length
m
Item
(2)
Reference Weight
kg
62.5/125 μm multimode
ber optic cables
equipped with MT-RJ connectors
For interconnecting the Ethernet ports on
140CPU67160 Primary and Standby
CPUs (8)
3 9 490NOR00003
5 9 490NOR00005
15 9 490NOR00015
9/125 μm single mode
ber optic cable
equipped with LC connectors
For interconnecting the Ethernet ports on
140CPU67261 Primary and Standby
CPUs (8)
5 9 VDIF0646463505
9/125 μm single mode
ber optic cable
equipped with LC and SC connectors
For connecting a PC, via a ConneXium
managed switch (6), to the Ethernet port on
the 140CPU67261 CPU (8)
(for updating the rmware, for example)
5 VDIF0626463505
Rack extension for Ethernet RIO drop
Description Length
m
Item
(2)
Reference Weight
kg
Rack expansion module
2 modules: 1 for the primary rack, 1 for the
secondary rack
10 140XBE10000(3)(4)
Cable for rack expansion module 1 11 140XCA71703
2 11 140XCA71706
3 11 140XCA71709
Requirements for a Quantum Ethernet I/O architecture (1)
The table below gives the minimum hardware and software requirements for setting
up a Quantum Ethernet I/O architecture.
Description of the hardware or software required Version Item
(2)
Unity
Pro Extra Large software u 6.0
Ethernet head adaptor 140CRP31200 1
Ethernet drop adaptor 140CRP31200 2
ConneXium managed switches
TSCESM083F23F1/063F2CU1/063F2CS1
Firmware u 6.0 5, 6
Quantum CPUs 140CPU65150/65160/65260 Firmware u 3.0 7
Quantum Hot Standby CPUs 140CPU67160/67261 Firmware u 3.0 8
Ethernet communication modules 140NOE77101 Firmware u 4.9 (6) 3
140NOE77111 Firmware u 5.0 (6) 3
(1) For additional specications, see our website www.schneider-electric.com.
(2) For items 1 to 7, see page 24.
(3) Conformal Coating version available for harsh environments with the application of Humiseal
1A33. In this case, add the letter “C” to the end of the reference.
(4) Certications (1): e, UL 508, CSA 22.2 No. 142, cUL, FM Class 1 Div. 2.
(5) Maximum data exchange volume:
- 140CPU67160: 1 MB
- 140CPU67261: 1.5 MB
(6) For management of Ethernet DIO devices via Ethernet communication module.
(7) Please refer to the relevant product catalogs on our website www.schneider-electric.com.
1 2
2
Quantum
Ethernet I/O
Ethernet RIO
Ethernet network
Ethernet RIO architecture
without ConneXium
managed switches
1010
11
7
Fiber optic
Ethernet network
Fiber optic
Ethernet network