Datasheet

73
15
E
2
K
Conguration of the Base Structure
15.4 Conguration of the Base Structure
15.4.2 Permissible Longitudinal Deviation E2 for MINIRAIL
and MINISCALE PLUS
Calculating height deviation E
2
E2 = K Vvsp
E2 = height deviation in mm
Q = carriage spacing in mm
V
vsp = preload factor (see following table)
Carriage dimensions, type MNNS (short) Preload factor Vvsp
7, 9, 12, 15 0.00010 K
Carriage dimensions, type MNN (standard) Preload factor V
vsp
7, 9, 12, 15 0.00005 K
14, 18, 24, 42 0.00004 K
Carriage dimensions, type MNNL (long) Preload factor V
vsp
7, 9, 12, 15 0.00004 K
14, 18, 24, 42 0.00003 K
Carriage dimensions, type MNNXL (extra long) Preload factor V
vsp
7, 9, 12, 15 0.00003 K
Calculation example for E
2
Example: Type MNNL 42
Spacing K = 700 mm
Calculation: Type MNNL 42 results in a preload factor Vvsp of 0.00003
0.00003 x 700 mm = 0.021 mm
Comment: The deviations of E2 must not exceed 0.021 mm.