Datasheet
42
Ua
1
+
Ua
0
+
Ua
2
+
Ua
2
-
Ua
0
-
Ua
1
-
2.3V
100μm
+
-
+
-
+
-
0.5V
≈100 μm
10
MINISCALE PLUS Product Overview
Single-ended Signals
Analog Interface Module Output
Differential Signals
Reference point
Sine
Cosine
Reference
10.2.3 Signal Processing
Further information about signal processing is available from the downloadsection
of our website www.schneeberger.com.
Analog output format:
Differential, sin/cos analog signals with reference pulse 1 Vpp (at 100 Ω).
The incremental signals sine and cosine are shifted 90° and correlated with the
markings on theencoded scale. An electrical signal period (360°) corresponds
precisely to the scale increment of the dimensional scale, which is 100 µm.
The reference pulse always marks electronically the same section of the path of the
sine and cosine signals. The point of intersection of the two signals within the
reference pulse therefore marks a precisely defined position on the dimensional
scale.
The sine signal either lags behind the cosine signal or occurs before it, depending
on the direction of movement.